Add the concentrate of reagent for flushing in the proportions recommended by the
manufacturer.
k.
Continue the procedure as recommended by the supplier of the reagent (but not
less than 30 minutes), control the indications of pressure gauges and consumption,
adjust the valves RV-01, RV-02, if it is necessary.
Note: The pressure at the inlet of the membrane should not exceed 2 - 2.5 bar.
l.
After flushing, put the switch "CONTROL RO» to
"OFF."
m.
Switch valves of the concentrate line to the working position, the hose of permeate
will be derived to the drain
.
Turn the valve V-01 (crane is opened) and CIP (crane is
closed or screw the blind) in the operating position
.
n.
Turn
the "CONTROL RO» to position «CIP», if
necessary, adjust the valve
RV-01.
o.
Continue treatment for about 15 minutes, than adjust the valves RV-
01…
RV-03 to
the operation conditions. Control the pressure gauge during the adjustment.
p.
Continue draining the permeate to the drain for at least 15 min, control the TDS
parameter shown on the TDS meter.
q.
If all indicators of devices are normal, switch the valves of permeate line into
operation position.
WARNING:
The system is flushed with chemicals. It is important to flush the RO
membranes after the chemical flushing. Incorrect adjustment of valves RV-01 ... RV-
03 may damage the membranes and high-pressure pump. The procedure should be
performed by trained staff only. If you do not have the appropriate skills in this area,
contact with your service.
10.
RULES OF STORAGE AND TRANSPORTATION
The RO system should be stored in a plastic packaging, in a closed carton, in closed
spaces with natural ventilation, with a relative humidity no higher than 80%, at a
temperature not lower than +3 °C and not higher than 50 °C.
Transportation and storage of the RO system are always in a vertical position. It is
forbidden to turn over the system and other mechanical changes.
The RO system must be transported within temperature limits of +3 °C up to + 50 °C.
Shelf life of the RO system before the beginning of usage is not more than 5 years
from date of manufacture, if all storage conditions are kept.