AQUAPHOR
PROFESSIONAL
WATER TREATMENT
L.Tolstoi
2A, Sillamäe,
40231 Estonia
www.pro.aquaphor.com
International: +372 356 2204 21
Skype: aquaphor market.pro
e-mail: [email protected]
7.
INSTALLATION OF REVERSE OSMOSIS SYSTEMS
7.1
Attention
The system must be installed in a dry place, out of direct sunlight. Excessive
moisture can cause failure of electrical components.
Make sure that the location of the installation is suitable and provide enough
space for servicing.
In case of mismatch of raw water requirements which are in a passport, install
the necessary elements of water treatment recommended by your service
representative or RO system supplier: multimedia filter, iron removal system,
filter based on coal sorbents, softener, ultrafiltration system, etc.
The frame of the RO system must be lined up and leveled.
In order to prevent malfunction of the RO system, the temperature in the room
where it is installed should be between
4 ÷ 45 °
C.
The level in the tank with permeate must not be higher than 1,5m above the
level of the permeate line (exit from the membrane), otherwise the system may
malfunction (for version without check valve on permeate line).
The diameter of the supply lines (permeate) must be less than the diameter of
the connecting lines of the RO system.
Please view carefully the drawing connections and check the characteristics of
the electrical network.
7.2
Connection
7.2.1
It is desirable to place the RO system close to the water supply and electricity
grid.
7.2.2
Connect the RO system to the raw water supply, permeate line and the drain
line respectively.
7.2.3
Connect the power, make sure that the frame of the RO system is grounded,
turn on the power, the power LED should light up.
7.2.4
In case of 3- phase power supply, check the rotation direction of the motor for a
few seconds.
7.2.5
Before supplying water to the RO system inlet, it is recommended to start-up
and wash each stage of prefiltration, if it is installed.