The operating parameters of the raw water
PARAMETERS
VALUE
Temperature of raw water
+5...+35 °C
Minimum pressure of raw water
40 PSI (2,8 kg/cm
2
)
Minimum flow of raw water
2,0 m
3
/h
Maximum concentrate to flow
1,25 m
3
/h
Operating temperature range
4
–
45 °C
Allowed (optimum) PH range
3 - 10 (7
–
7,5)
Hardness
Not more 17 (ppm)
Turbidity
Not more 5 SDI
Mineral oil
-
Salinity (TDS)
5000 mg/l
Fe total
Not more than 0,1mg/l
Oxidizers (chlorine, ozone, KMnO4)
Not more than 0,1 mg/l
Manganese (Mn)
Not more than 0,05 mg/l
Organic impurities
Not more than 5 mgO
2
/l
Note:
In the case of non-compliance of your water requirements, Additional stages of
treatment may be required we will recommend the most suitable system upon your