53
Alarm №
Symptoms
Possible causes
Corrective Action
Alarm-01
Low level in
the raw water
tank
Low level in the raw water tank T-
01
Check the presence of raw water; other-
wise, check RO water supply and LLS-
01 functionality.
Alarm-02
Pretreatment
system error
The pre-filtration system is in the
PTS-01 regeneration mode for > 3
hours
Check the functionality of pretreatment
equipment, RO system controller cable,
and pretreatment system controller.
Alarm-03
Antiscalant
tank low level
No signal from the LLS-02 in the
antiscalant T-02 tank for 10 sec-
onds.
Check the presence of antiscalant or/and
sensor functionality
Alarm-04
Raw water
low pressure
No signal from the LPS-01 in the
supply line for a specified time
(Setup. -06)
Check RO water supply and LPS-01
functionality.
Alarm-05
Low inlet
pressure
No signal from the LPS-02 in the
water supply line to the RO system
for a specified time (Setup-06).
Check the functionality of RO water sup-
ply, LPS-02, XV-01.
Alarm-06
High inlet
pressure to RO
membrane
unit
No signal from the HPS-02 at the
membrane inlet for 10 seconds.
Perform CIP or change the membrane,
check HPS-02 functionality.
Alarm-07
RO pump
overload
A signal is received from the ther-
mal protection of the pump motor
of the RO system P-01.
Check RO pump P-01 overload function-
ality.
Alarm-08
High electrical
conductivity
of permeate
The conductivity value of the RO
system product is bigger than the
set value (Setup-04) for 5 minutes
Perform PCP-01 calibration, perform
CIP, or change the membrane.
Alarm-09
Minimum
value of per-
meate flow
The osmosis system permeate flow
value is less than the set value
(Setup-14) for 5 minutes.
Check the functionality of FT-01. Per-
form CIP, or change the membrane.
Alarm-10
Minimum
concentrate
flow
The osmosis system permeate flow
value is less than the set value
(Setup-14) for 5 minutes.
Check the functionality of the concen-
trate sensor and automatic concentrate
valve XV-04.
Alarm-11
Low permeate
level
There is no signal from the LLS-03
low water level sensor in the T-03
permeate tank for 20 minutes.
Check permeate presence in the tank.
Alarm-12
High feed con-
ductivity
The conductivity of the raw water
of the RO system is greater than the
set value for 5 minutes
Check the raw water supply, functional-
ity of ECT-02 and pretreatment system.
Alarm-14
Feed pressure
sensor
The feed pressure value is lower
than the set value (Setup-17) for 5
minutes
Check the sensor and cable connection.
If there is an error after checking, then
replace the sensor.
Alarm-15
Inlet pressure
sensor
The inlet pressure value is lower
than the set value (Setup-18) for 5
minutes
Check the sensor and cable connection.
If there is an error after checking, then
replace the sensor.
Alarm-16
RO pressure
sensor
The RO pressure value is higher
than the set value (Setup-19) for 5
minutes
Check the sensor and cable connection.
If there is an error after checking, then
replace the sensor.
Alarm-17
Permeate pres-
sure sensor
The permeate pressure value is
higher than the set value (Setup-20)
for 5 minutes
Check the sensor and cable connection.
If there is an error after checking, then
replace the sensor.
Содержание APRO 1000 LPH
Страница 1: ...aquaphor pro com TP APRO WH R02 APRO WH 1000 LPH WATER PURIFICATION SYSTEM...
Страница 8: ...8 aquaphor pro com TP APRO WH R03 2 SYSTEM OVERVIEW APRO WH 1000 LPH system dimensions...
Страница 9: ...9 aquaphor pro com TP APRO WH R03...
Страница 13: ...13 aquaphor pro com TP APRO WH R03 3 2 ELECTRIC CIRCUIT SCHEMES...
Страница 14: ...14 aquaphor pro com TP APRO WH R03...
Страница 15: ...15 aquaphor pro com TP APRO WH R03...
Страница 16: ...16 aquaphor pro com TP APRO WH R03...
Страница 17: ...17 aquaphor pro com TP APRO WH R03...
Страница 18: ...18 aquaphor pro com TP APRO WH R03...
Страница 19: ...19 aquaphor pro com TP APRO WH R03...
Страница 20: ...20 aquaphor pro com TP APRO WH R03...
Страница 80: ...80 14 ADDITIONAL MATERIALS...
Страница 81: ...81...
Страница 83: ...83 REMARKS...