The Pool Pilot DIG-220 is a salt chlorination system designed for pool or spa water purification. Although

 

the DIG-220 is easy to use, it is important to read through the entire manual before attempting to 

operate

 

the system.

How Your Chlorine Generator Works

The system requires a low concentration of dissolved salt (sodium chloride) in the 

water. The

 salt  concentration

 

level is normally maintained below the taste threshold. The DIG-220 automatically converts the salt into chlorin

 

which your pool/spa requires to remain sanitized and algae free. The chlorine reverts back to salt after treating

 

the water.

Since the salt is constantly recycled, there is minimal loss during a swimming season.

However, salt can be lost due to filter backwashing, rain water 

over flow, leaks

, or bather

splashing/carry out... but 

not

 through evaporation.

The amount of chlorine required for proper sanitization will vary based on the pool

size and various factors such as water temperature, bather load, exposure to direct

sunlight, and special water features.
The water circulation pump must be operating for your DIG-220 to produce chlorine,

so run time is one of several key components to maintaining the proper sanitizer levels.

Most installations require a minimum of eight (8) hours-per-day pump run time

to properly filter and sanitize the water.

Control Overview

Following is a brief explanation of owner / operator control options. For full features of the Owner Options

Menu, please 

see page-20 & 21

. The MENU button is pressed to obtain access to the Owner Options Menu.

Please Note:  

This quick start section assumes the installer has already programmed the system for

specific site parameters, has established proper water balance, and has pretreated water to 1 - 3 ppm

chlorine.

Attention Owner:

  Should Celsius vs. Fahrenheit, choice of language, or other owner options require

modification, please refer to 

Operation of Buttons 

located on page-18

 and 

Owner Options 

on 

page-20

& 21

.

Use the UP and DOWN arrows to control 

the

 purifier

 output

 

level

, then press the SELECT button to save the value chosen.

 

With a properly prepared

 

pool, the recommended starting output

 

level is 50%.

Up and Down Arrows:

Please Note:

 The 

optimum output setting 

will vary based upon pool size, location, exposure to sunlight,

 

number  of  users,  veget

a

tion  around  the  pool,  water  balance  practices,  and  pump  run  time.

 

Your 

installer

 

should  have  already  taken  these  factors  into  consideration  when  performing  installation 

programming.

 

Therefore, your adjustments, at this point, should be relatively minor.

n

After the purifier output level is “tuned in,” the unit will automatically make fine output adjustments as the

 

water temperature fluctuates. This 

patented

 temperature compensation feature will adjust output depending

 

on water temperature. See page-10 & 30 for more information concerning the temperature compensatio

 

feature.

OWNER QUICK START & RUN

e,

Upon initial start-up, check sanitizer level every few days

and make small output level adjustments as necessary to

maintain 1-3 ppm free chlorine levels.
Your DIG-220 does 

not

  directly measure or regulate the sanitizer

levels in your pool. Rather, the owner / operator will need to

periodically test the water to determine the current chlorine

level, and adjust the 

output setting 

as needed.

FIG-1

Purifier

12:00 pm       80F

100%

Содержание DIG-220

Страница 1: ...0 DIG R13 Owner s Manual Salt Chlorine Generator IMPORTANT Swimming Pool Spa Purification System Read This Manual Before Installing or Operating Installation and Operation This manual covers the insta...

Страница 2: ...Requirements 14 For incoming voltage of 230 Vac 14 For incoming voltage of 115 Vac 15 Connecting DIG 220 to External Equipment 15 Connecting DIG 220 to ExternalTime Clock 15 Connecting DIG 220 to Cont...

Страница 3: ...t Remote 23 Select Minerals 23 Pump Program 1 and2 23 Enable Demo 23 REFERENCE SECTION 24 26 SaltAddition Chart 24 Basic Water Chemistry 24 25 Using the Saturation Index SI 25 26 Part Numbers 26 MAINT...

Страница 4: ...f harsh chemical reactions like red eyes green hair itchy skin or faded swim wear Our product makes it easy to retain a constant level of chlorine purifying the water while making it soft and silky to...

Страница 5: ...e sure to leave your name a complete address and your telephone number Or if you prefer you may FAX us at 877 408 8142 Be certain to provide your full address and a daytime telephone number To Contact...

Страница 6: ...th WARNING All field installed metal components such as rails ladders drains or similar hardware within 10 3 m of the spa or hot tub shall be bonded to the equipment grounding bus with copper conducto...

Страница 7: ...lease Note This quick start section assumes the installer has already programmed the system for specific site parameters has established proper water balance and has pretreated water to 1 3 ppm chlori...

Страница 8: ...ee troubleshooting section on page 21 Check System Light Flashes if the water flow is insufficient under the following circumstances When DIG 220 is not set up to control the water pump uses an Extern...

Страница 9: ...oduction of your DIG 220 Please note the following recommended water chemistry parameters See Basic Water Chemistry on page 24 25 and Using the Saturation Index on page 25 26 for further information c...

Страница 10: ...view for details and diagrams Important Features Patented temperature compensation for chlorine output control Programmable microprocessor control Multi language digital display English Spanish Italia...

Страница 11: ...his manual Determine origination point for control center power feed Directly from a circuit breaker From an external timer or From an electronic controller Determine everything needed for installatio...

Страница 12: ...concentration level The DIG 220 uses this data to determine if conditions are safe for the Pool Pilot Cell to operate the signal read from the temperature sensor allows the automatic temperature comp...

Страница 13: ...device before operating equipment Failure to heed the following may result in equipment damage NOTICE To avoid over saturation conditions of your spa it is suggested to locate the cell downstream of...

Страница 14: ...ontractor perform the electrical connections Failure to heed the following may result in permanent injury or death WARNING Mounting the Control Unit Continued Read the following section complety befor...

Страница 15: ...eed Pump or Two Speed Pump connections Select the diagram that matches your application Wiring diagram also located on inside of cover Connecting DIG 220 to External Time Clock FIG 12 TAB 7 TAB 9 230V...

Страница 16: ...speed when internal time clock program does not have the pump operating on high speed A safety shut off wall switch between the circuit breaker and control box is recommended when the circuit breaker...

Страница 17: ...or available types of tablet or granular chlorine as obtained from pool supply to achieve 1 3 ppm free chlorine 4 Add salt to water test the water for salt level first Adjust to 3000 ppm See salt char...

Страница 18: ...l or whether the system is in Boost or Super Boost mode The Second line of the display shows the current TIME in either 12 or 24 hr mode the TEMPERATURE in either Fahrenheit or Celsius whether the cel...

Страница 19: ...for 24 Hours From the normal operation mode press and release the BOOST button The display will flash Boost 24 hour then Boost hh with the hh actually being the displayed hours remaining in the boost...

Страница 20: ...nce menu 1 Press MENU press or until View Setup is displayed then press SELECT 2 allows manual control forward and back While in this feature pressing MENU The display will automatically toggle throug...

Страница 21: ...The display will automatically toggle through the following displays or allows manual control forward and back While in this feature pressing MENU will override the remaining displays and exit back t...

Страница 22: ...ng is 15 000 gallons The range is 500 to 127 500 gallons 1 000 to 226 000 liters 3 Press or until correct pool size is displayed then press SELECT Programming at Installation NOTE Once determined to b...

Страница 23: ...mote runs pump in order to use this option Pump Program 1 and 2 1 Press or until Pump program X is displayed then press SELECT 2 Press to program the pump press D to Delete the program or SELECT to ex...

Страница 24: ...various columns 1 000 2 000 5 000 10 000 15 000 20 000 25 000 30 000 35 000 40 000 4 000 8 000 18 000 38 000 56 000 76 000 94 000 114 000 132 000 152 000 25 50 125 250 376 501 626 751 876 1 002 11 23...

Страница 25: ...ool with fresh water to dilute Diluting will reduce salt and CYA Check and adjust as needed Please note in some areas there may be higher than recommended calcium levels in the tap water If this level...

Страница 26: ...2 1 12 4 0 Water is perfectly balanced Water Test Results 1 FIG 24 Using the Saturation Index SI Continued APA0003 Tri sensor with integrated cord FIG 29 MANIFOLD UNION w Strainer 19065 Union O Ring...

Страница 27: ...age could occur if the pump activates Failure to heed the following may result in permanent injury or death WARNING Failure to heed the following may result in equipment damage NOTICE If the manifold...

Страница 28: ...ced 4 The Tri sensor can now be pulled out of the Tee Firmly grip theTri Ssnsor assembly this is typically done with a large pair of channel lock pliers Twist the Tri sensor back and forth while simul...

Страница 29: ...maintain water in a balanced condition Water main tained in a scaling condition will shorten cell life and may render the chlorina tor inoperative Damage and or service calls caused by improper water...

Страница 30: ...ed for One speed pump see pg 34 When the Tri sensor indicates that water temperature is below 38 F 4 4 C the Control Unit will override the normal timed program cycle and run the pump 30 minutes minim...

Страница 31: ...zer Cyanuric acid level 5 White Flakes in the Water This occurs when excessive calcium hardness is present Usually due to waterchemistry imbalance Adjust your water chemistry visually inspect Cell for...

Страница 32: ...er generation during this display 16 CHECK SYSTEM Light Flashing Message Displayed Pwr Ctrl Error 15 CHECK SYSTEM Light Flashing Contact the factory for Warranty Status Procedures 14 A small dot walks...

Страница 33: ...d to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential i...

Страница 34: ...34 2737 24th St North St Petersburg FL 33713 727 823 5642...

Отзывы: