Pump Button - 

One-Speed Pump Control

The DIG-220 must be wired to control the main circulation pump and programmed for a One-Speed pump for this feature to be 

acti

ve (for more information on wiring, 

see

 

page-15 & 16, and for pump control programming, see page-23). Note - optional pump relay must be installed.

1.

Press Pump.

2.

Press  - Stop Pump will be displayed. Press 

3.

“Pump off” will be displayed.

„

To turn “

PUMP OFF

” , when pump is on:

1.

Press Pump.

2.

Press  - Stop Pump will be displayed. Press 

3.

“Pump off for service” will be displayed.

„

To turn “

PUMP OFF FOR SERVICE

”, when pump is off:

1.

Press Pump.

2.

Press 

- End Maint.

3.

“Pump off” will be in the displayed.

„

To 

terminate maintenance mode

 and return to “PUMP OFF”  mode:

1.

Press Pump.

2.

Press 

- to start pump.

3.

The pump will run until the pump program reaches the next scheduled turn off time.

„

To turn “

PUMP ON

”, when pump is off:

Pump Button...

(This button is not active if the Pump Configuration is programmed for “External Timer” or “Remote runs pump”.  If the Pump 

button 

is pressed when programmed for one of 

these

 

modes, ”External Time” or ”Remote runs pump” will display, then revert back to the normal display.)

(This mode disables pump operation indefinitely, until manually enabled. Boost and Pump program modes will not enable pump.)

ACCESS TO PROGRAMMING

MENU OVERVIEW

Control Panel:

Operation of Buttons:

The following instructions apply to software versions 4.40 and above. Earlier versions of

 software

 

will vary slightly.

After 30 minutes of inactivity, the display will go to a walking dot screen saver

 mode. 

 A

 

 ll functions such as chlorine generation, reverse, boost, etc., will continue in the background

.

 

Pressing any key will call up the normal informational displa.y

The First line of the display shows the Purifier Output Level in percent (set to 50% at install), or whether the system is

 in Boost 

or Super-Boost mode.

The Second line of the display shows the current

 

 TIME in either 12 or 24-hr mode,

 the 

 

 

 TEMPERATURE in either Fahrenheit or Celsius,  whether the cell is powered

 

or 

not shown as “ON” or “OFF”,  and Polarity Direction shown as a “.” or blank.

Select Button...

The SELECT button chooses the displayed menu option. For t

he 

Installer Menu

,

 press and hold the SELECT button for approximately 13-seconds to access this feature.

Menu Button...

The MENU button is used to leave the normal operation mode and enter the program and diagnostic modes.  Use the UP/DOWN

 and 

SELECT buttons to navigate through

 

the 

menus and sub-menus.
MAIN MENU:

„

Test Pool Pilot 

- displays various operating parameters and diagnostic results

„

View Setup - displays the programmed setup parameters

„

Owner Options - programs the primary operating parameters an owner would need to change

„

Maintenance Menu - tests and programs the primary features a service technician would need to access when servicing the system

„

Installer Menu - program the initial system setup

Note: to permit quick access to features, some functions are accessed or programmed in several menus.

The DISPLAY 

Press 

BOOST

  to  start  24-hour  boost  mode, 

o

press and hold

 

 

BOOST 

for 8-seconds to start 

72-

 

hour  boost  mode.  Press

  BOOST

  again  to 

cancel

 

boost.

CHECK SYSTEM

 – Red

LED flashes when the

circulation pump is off or to

warn attention is required. A

warning message will also

be displayed.See

troubleshooting on page-31

& 32.

Press  the 

UP 

or

DOWN 

arrow to:

ƒ

Set Chlorine Level %*

ƒ

Scroll through Menus

and sub-Menus

ƒ

Increase or Decrease

programming values

for menus

.

Press 

MENU 

to leave normal

operation to access the menus for

programming and diagnostics.

Press the 

SELECT

 button

to choose the item currently

displayed.

*Make Initial Setting at

install  50%.

PUMP

 – 

 over ride the water

pump timer,  temporarily

turning  the pump on or off

(if wired & programmed to

control the circulation

pump).

Purifier
12:00 pm       80F       ON

50%

FIG-19

Содержание DIG-220

Страница 1: ...0 DIG R13 Owner s Manual Salt Chlorine Generator IMPORTANT Swimming Pool Spa Purification System Read This Manual Before Installing or Operating Installation and Operation This manual covers the insta...

Страница 2: ...Requirements 14 For incoming voltage of 230 Vac 14 For incoming voltage of 115 Vac 15 Connecting DIG 220 to External Equipment 15 Connecting DIG 220 to ExternalTime Clock 15 Connecting DIG 220 to Cont...

Страница 3: ...t Remote 23 Select Minerals 23 Pump Program 1 and2 23 Enable Demo 23 REFERENCE SECTION 24 26 SaltAddition Chart 24 Basic Water Chemistry 24 25 Using the Saturation Index SI 25 26 Part Numbers 26 MAINT...

Страница 4: ...f harsh chemical reactions like red eyes green hair itchy skin or faded swim wear Our product makes it easy to retain a constant level of chlorine purifying the water while making it soft and silky to...

Страница 5: ...e sure to leave your name a complete address and your telephone number Or if you prefer you may FAX us at 877 408 8142 Be certain to provide your full address and a daytime telephone number To Contact...

Страница 6: ...th WARNING All field installed metal components such as rails ladders drains or similar hardware within 10 3 m of the spa or hot tub shall be bonded to the equipment grounding bus with copper conducto...

Страница 7: ...lease Note This quick start section assumes the installer has already programmed the system for specific site parameters has established proper water balance and has pretreated water to 1 3 ppm chlori...

Страница 8: ...ee troubleshooting section on page 21 Check System Light Flashes if the water flow is insufficient under the following circumstances When DIG 220 is not set up to control the water pump uses an Extern...

Страница 9: ...oduction of your DIG 220 Please note the following recommended water chemistry parameters See Basic Water Chemistry on page 24 25 and Using the Saturation Index on page 25 26 for further information c...

Страница 10: ...view for details and diagrams Important Features Patented temperature compensation for chlorine output control Programmable microprocessor control Multi language digital display English Spanish Italia...

Страница 11: ...his manual Determine origination point for control center power feed Directly from a circuit breaker From an external timer or From an electronic controller Determine everything needed for installatio...

Страница 12: ...concentration level The DIG 220 uses this data to determine if conditions are safe for the Pool Pilot Cell to operate the signal read from the temperature sensor allows the automatic temperature comp...

Страница 13: ...device before operating equipment Failure to heed the following may result in equipment damage NOTICE To avoid over saturation conditions of your spa it is suggested to locate the cell downstream of...

Страница 14: ...ontractor perform the electrical connections Failure to heed the following may result in permanent injury or death WARNING Mounting the Control Unit Continued Read the following section complety befor...

Страница 15: ...eed Pump or Two Speed Pump connections Select the diagram that matches your application Wiring diagram also located on inside of cover Connecting DIG 220 to External Time Clock FIG 12 TAB 7 TAB 9 230V...

Страница 16: ...speed when internal time clock program does not have the pump operating on high speed A safety shut off wall switch between the circuit breaker and control box is recommended when the circuit breaker...

Страница 17: ...or available types of tablet or granular chlorine as obtained from pool supply to achieve 1 3 ppm free chlorine 4 Add salt to water test the water for salt level first Adjust to 3000 ppm See salt char...

Страница 18: ...l or whether the system is in Boost or Super Boost mode The Second line of the display shows the current TIME in either 12 or 24 hr mode the TEMPERATURE in either Fahrenheit or Celsius whether the cel...

Страница 19: ...for 24 Hours From the normal operation mode press and release the BOOST button The display will flash Boost 24 hour then Boost hh with the hh actually being the displayed hours remaining in the boost...

Страница 20: ...nce menu 1 Press MENU press or until View Setup is displayed then press SELECT 2 allows manual control forward and back While in this feature pressing MENU The display will automatically toggle throug...

Страница 21: ...The display will automatically toggle through the following displays or allows manual control forward and back While in this feature pressing MENU will override the remaining displays and exit back t...

Страница 22: ...ng is 15 000 gallons The range is 500 to 127 500 gallons 1 000 to 226 000 liters 3 Press or until correct pool size is displayed then press SELECT Programming at Installation NOTE Once determined to b...

Страница 23: ...mote runs pump in order to use this option Pump Program 1 and 2 1 Press or until Pump program X is displayed then press SELECT 2 Press to program the pump press D to Delete the program or SELECT to ex...

Страница 24: ...various columns 1 000 2 000 5 000 10 000 15 000 20 000 25 000 30 000 35 000 40 000 4 000 8 000 18 000 38 000 56 000 76 000 94 000 114 000 132 000 152 000 25 50 125 250 376 501 626 751 876 1 002 11 23...

Страница 25: ...ool with fresh water to dilute Diluting will reduce salt and CYA Check and adjust as needed Please note in some areas there may be higher than recommended calcium levels in the tap water If this level...

Страница 26: ...2 1 12 4 0 Water is perfectly balanced Water Test Results 1 FIG 24 Using the Saturation Index SI Continued APA0003 Tri sensor with integrated cord FIG 29 MANIFOLD UNION w Strainer 19065 Union O Ring...

Страница 27: ...age could occur if the pump activates Failure to heed the following may result in permanent injury or death WARNING Failure to heed the following may result in equipment damage NOTICE If the manifold...

Страница 28: ...ced 4 The Tri sensor can now be pulled out of the Tee Firmly grip theTri Ssnsor assembly this is typically done with a large pair of channel lock pliers Twist the Tri sensor back and forth while simul...

Страница 29: ...maintain water in a balanced condition Water main tained in a scaling condition will shorten cell life and may render the chlorina tor inoperative Damage and or service calls caused by improper water...

Страница 30: ...ed for One speed pump see pg 34 When the Tri sensor indicates that water temperature is below 38 F 4 4 C the Control Unit will override the normal timed program cycle and run the pump 30 minutes minim...

Страница 31: ...zer Cyanuric acid level 5 White Flakes in the Water This occurs when excessive calcium hardness is present Usually due to waterchemistry imbalance Adjust your water chemistry visually inspect Cell for...

Страница 32: ...er generation during this display 16 CHECK SYSTEM Light Flashing Message Displayed Pwr Ctrl Error 15 CHECK SYSTEM Light Flashing Contact the factory for Warranty Status Procedures 14 A small dot walks...

Страница 33: ...d to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential i...

Страница 34: ...34 2737 24th St North St Petersburg FL 33713 727 823 5642...

Отзывы: