18
Pump Button -
One-Speed Pump Control
The DIG-220 must be wired to control the main circulation pump and programmed for a One-Speed pump for this feature to be
acti
ve (for more information on wiring,
see
page-15 & 16, and for pump control programming, see page-23). Note - optional pump relay must be installed.
1.
Press Pump.
2.
Press - Stop Pump will be displayed. Press
3.
“Pump off” will be displayed.
To turn “
PUMP OFF
” , when pump is on:
1.
Press Pump.
2.
Press - Stop Pump will be displayed. Press
3.
“Pump off for service” will be displayed.
To turn “
PUMP OFF FOR SERVICE
”, when pump is off:
1.
Press Pump.
2.
Press
- End Maint.
3.
“Pump off” will be in the displayed.
To
terminate maintenance mode
and return to “PUMP OFF” mode:
1.
Press Pump.
2.
Press
- to start pump.
3.
The pump will run until the pump program reaches the next scheduled turn off time.
To turn “
PUMP ON
”, when pump is off:
Pump Button...
(This button is not active if the Pump Configuration is programmed for “External Timer” or “Remote runs pump”. If the Pump
button
is pressed when programmed for one of
these
modes, ”External Time” or ”Remote runs pump” will display, then revert back to the normal display.)
(This mode disables pump operation indefinitely, until manually enabled. Boost and Pump program modes will not enable pump.)
ACCESS TO PROGRAMMING
MENU OVERVIEW
Control Panel:
Operation of Buttons:
The following instructions apply to software versions 4.40 and above. Earlier versions of
software
will vary slightly.
After 30 minutes of inactivity, the display will go to a walking dot screen saver
mode.
A
ll functions such as chlorine generation, reverse, boost, etc., will continue in the background
.
Pressing any key will call up the normal informational displa.y
The First line of the display shows the Purifier Output Level in percent (set to 50% at install), or whether the system is
in Boost
or Super-Boost mode.
The Second line of the display shows the current
TIME in either 12 or 24-hr mode,
the
TEMPERATURE in either Fahrenheit or Celsius, whether the cell is powered
or
not shown as “ON” or “OFF”, and Polarity Direction shown as a “.” or blank.
Select Button...
The SELECT button chooses the displayed menu option. For t
he
Installer Menu
,
press and hold the SELECT button for approximately 13-seconds to access this feature.
Menu Button...
The MENU button is used to leave the normal operation mode and enter the program and diagnostic modes. Use the UP/DOWN
and
SELECT buttons to navigate through
the
menus and sub-menus.
MAIN MENU:
Test Pool Pilot
- displays various operating parameters and diagnostic results
View Setup - displays the programmed setup parameters
Owner Options - programs the primary operating parameters an owner would need to change
Maintenance Menu - tests and programs the primary features a service technician would need to access when servicing the system
Installer Menu - program the initial system setup
Note: to permit quick access to features, some functions are accessed or programmed in several menus.
The DISPLAY
–
Press
BOOST
to start 24-hour boost mode,
o
r
press and hold
BOOST
for 8-seconds to start
72-
hour boost mode. Press
BOOST
again to
cancel
boost.
CHECK SYSTEM
– Red
LED flashes when the
circulation pump is off or to
warn attention is required. A
warning message will also
be displayed.See
troubleshooting on page-31
& 32.
Press the
UP
or
DOWN
arrow to:
Set Chlorine Level %*
Scroll through Menus
and sub-Menus
Increase or Decrease
programming values
for menus
.
Press
MENU
to leave normal
operation to access the menus for
programming and diagnostics.
Press the
SELECT
button
to choose the item currently
displayed.
*Make Initial Setting at
install 50%.
PUMP
–
over ride the water
pump timer, temporarily
turning the pump on or off
(if wired & programmed to
control the circulation
pump).
Purifier
12:00 pm 80F ON
50%
FIG-19