11
SPECIFICATIONS
230 Vac (1.5 AC amps) 50/60 Hz (default from factory)
115 Vac (3 AC amps) (easily converted in the field, refer t
o
page-14 & 15 for instructions
on conversion)
@ Cell Power 3 (8 amps DC)
(set at 100% - 24 hour operation)
2.
62
lbs/day (1.1
9
kg/day)
1.92 lbs/day (0.88 kg/day)
1.56 lbs/day (0.71 kg/day)
PPC5
PPC4
PPC3
PPC1
1.28 lbs/day (0.58 kg/day)
Cell Power 1 (5* DC amps)
Cell Power 2 (6.5* DC amps)
Cell Power 3 (8* DC amps)
* Indicates nominal amperage output. The dual axis controller
will slightly vary the amps to optimize the power to the cell.
Input Power:
Output Power:
Chlorine Output:
Voltage Input ................... Amps / HP max
115 Vac ............................ 30 amps / 1 HP
230 Vac ............................ 30 amps / 2.5 HP
Optional Internal Pump Relay Ratings:
Maximum Operating Pressure: 50 psi
Maximum Flow Rate: 100 gpm
Minimum Flow Rate: 20 gpm
Manifold Flow Requirements:
A Note Concerning Terminology:
Throughout this manual, the portion of the system which mounts to the wall (and powers the cell) may be referred to as
the
DIG-220
or
unit
. In addition, when “pool” is
referred
to in the absence of the word “spa,” it should be assumed “spa” is inferred (should a spa be present in the installation).
Agency Approvals:
ETL tested to confirm to UL1081 specification. Standard for Safety for Swimming Pool
Pumps, Filters and Chlorinators.
NSF/ANSI 50 ............................. Circulation System components and related materials
for swimming pools, spas/hot tubs.
CAN/CSA-E335-1 ...................... General Requirements For Safety of Household and
Similar Electrical Appliances.
See appendix on page-33 for CE Declaration of
Conformity
Before Installing:
Installer... Please record the following information on page-4 of this manual:
Date of Installation
Pool Pilot
Cell Type
Control Unit Model
Pool Pilot
Cell Serial Number
Control Unit Serial Number
For questions concerning installation or operation of this equipment:
Visit www.autopilot.com for latest manual revisions and helpful troubleshooting tips.
You can also contact AquaCal AutoPilot
, Inc.
customer support as specified
on pa
ge-5
of this manual.
Determine origination point for control center power feed:
Directly from a circuit breaker...
From an external timer, or
From an electronic controller
Determine everything needed for installation is on hand.
Determine where the Manifold Assembly will be plumbed.
Identify a suitable mounting location for the DIG-220 within proper cord length to the manifold. If possible, avoid locatio
n wit
h direct sunlight, sprinklers, etc.
Plan runs for
Pool Pilot
Cell and Tri-
s
ensor Cables. (Cables are 12’ or 3
.
65M)
Plan wire runs and wiring connections for source power.
DIG-220 is to be wired to the same location as the circulation pump; the unit is activated only when the
circulation pump is energized.
Circuit breaker is used to power the DIG-220 and circulation pump.
Determine whether the input voltage for the DIG-220 will be 115-Vac or 230-Vac
Determine whether the DIG-220 will be used to control a single speed or a two speed pump. (Optional pump relay m
u
st be installed
)
Determine whether the DIG-220 will be controlled by an ORP controller.
Determine whether the DIG-220 will be controlled by an Electronic Controller System.
What is included:
Although the manifold assembly may be sold separately, both a manifold and a Digital Control Center are required for a complete installation. The standard cell & manifold assembly
is available with the following cells:
PPC1, PPC3, PPC4 and PPC5
. Before attempting the installation, verify the
following item
s have been included with the Control Center:
FIG-5
Quantity
Item Description
1
4
1
1
DIG-220 Control Center / Power Supply
Screws and Screw Anchors
Drilling Template
Manual
1
6 amp fuse, and wire jumper kit
1
Cell Cable
68mm x 2” metric adaptors (#19059)
* European systems only
*
2
CHEC K
S YSTEM
BOOST MENU SELECT PUMP
Screws and Anchors
Power Supply
Cell Cable
What is not included:
Power service electrical wire.
½" liquid tight (nonmetallic flex) conduit.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device ma
y
not cause harmful interference, and (2) this
device
must accept any interference received, including interference that may cause undesired operation.