9
Winterizing
Freeze Protection & Extended Shut Down:
Information Critical to the Survival of Your
DIG-
220 Follows...
In areas where freezing conditions are a rare occurrence, allow the filtration system to run continuously
throughout the freeze period. Typically, during light freeze conditions, circulating (moving) water will not
freeze.
I
n areas where freezing conditions are prevalent and sustained, the DIG-22
0
MUST
b
e winterized;
please
refer to winterizing instructions on
page-30
.
OWNER QUICK START & RUN
(CONTINUED)
Proper water balance is critical to the operation of your DIG-220.
Conditions such as high pH levels, low cyanuric acid (stabilizer ) levels, or other factors
causing
unbalanced
water,
will mask the sanitizer production of your DIG-220. Please note the following recommended water
chemistry parameters:
See “Basic Water Chemistry,” on
page-24 & 25
, and “Using the Saturation Index,” on
page
-25 & 26 for
further
information concerning pool/spa water chemistry maintenance requirements.
PH........................................:
Calcium Hardness....................:
Total Alkalinity.........................:
Salt.......................................:
Cyanuric Acid (stabilizer )..........:
Chlorine.................................:
Should you have additional water balance or chemistry questions, please refer to
the Tro
ubleshooting
section
in the back of this manual.
Water Balance & Chemistry Recommendations
)
7.2 – 7.8
200 – 400 ppm
80 – 100 ppm
2500 –
4
500 ppm (ideal 3000 ppm
60 – 80 ppm
1 – 3 ppm
Failure to heed the following may result in equipment damage.
NOTICE
Special measures are required in the event of freezing conditions.
Your DIG-220 may be damaged if measures are not taken in advance of freez-
ing conditions. Equipment damage due to freezing conditions is NOT covered
under the equipment warranty.
Important !!!