26
Part Numbers:
REFERENCE SECTION
Examples:
pH = 7.8 ..................................................................................... :
Water Temperature = 84 F ....................................................... :
Calcium Hardness = 600 ppm ................................................. :
Total Alkalinity = 200 ppm......................................................... :
Salt Level = 3200 ppm............................................................... :
7.8 + 0.7 + 2.4 + 2.3 - 12.4 = 0.8 (Water is scale forming)
Water Test Results #2
pH = 7.8
TF = 0.7
CF = 2.4
AF = 2.3
SC = 12.4
pH = 7.4 ..................................................................................... :
Water Temperature = 84 F ....................................................... :
Calcium Hardness = 400 ppm ................................................. :
Total Alkalinity = 125 ppm......................................................... :
Salt Level = 3200 ppm ............................................................... :
pH = 7.4
TF = 0.7
CF = 2.2
AF = 2.1
SC = 12.4
7.4 + 0.7 + 2.2 + 2.1 – 12.4 = 0 (Water is perfectly
balanced)
Water Test Results #1
(FIG-24)
Using the Saturation Index (SI) Continued:
(#APA0003)
Tri-
s
ensor with
integrated cord
FIG-29
MANIFOLD UNION
w/Strainer
(#19065)
Union O-Ring
(#19062)
Union Nut
S t r a i n e r
(#19064)
FIG-26
12’ (3.6 m)
Cell Cord
(# 952-ST/DIG)
Red Cap Plug
for
PPC1
and
PPC3
cell cord
(#19050)
FIG-27
MANIFOLD ASSEMBLY (STK0035):
(Tri-
s
ensor and Cell sold seperately)
FIG-25
Electrolytic Cell:
(Cell Unions and Cord ordered separately)
UNION COMPLETE
(#19070)
Cell (#’s
PPC1, PPC3, PPC4, PPC
5
)
2” Slip Union
(#312-B)
(51 mm)
Nut only for 2” Slip
Union
(#312-A) (51 mm)
Union O-Ring
(#19070-0)
FIG-28