21
PROGRAMMING
(CONTINUED)
Select Units:
1.
Press or
until “
Select Units
” is displayed; then press SELECT (
“English Units”
is the factory setting).
2.
Press or
until desired measurement “
English Units
” (gallons and pounds), or “
Metric Units
” (liters and kilograms), is displayed; then press SELECT.
(Used to program the operator’s personal preferences for the liquid and weig
hts
measurement the DIG-220 will display.)
Temperature Units:
1.
Press or
until “
Temperature Unit
” is displayed; then press SELECT (
“Fahrenheit”
is the factory setting).
2.
Press or
until desired measurement unit “
Fahrenheit
” or “
Celsius
” is displayed; then press SELECT.
(Used to set the personal preference (C or F) for temperature display
.)
12/24 Hour Clock:
1.
Press or
until “
12/24 hour clock
” is displayed; then press SELECT (12 hour clock is the factory setting).
2.
Press or
until the desired clock format (12-hour or 24-hour clock) is displayed, then press SELECT
.
(Allows for personal preference time clock display)
Exit Menu Mode:
Press SELECT to exit menu entry.
Set Time of Day:
1.
Press or
until desired hours are displayed; then press SELECT.
2.
Press or
until the desired minutes are displayed; then press SELECT.
(Allows for changes to the time of day displays for time zones or day-light savings.)
Owner Options Continued:
Maintenance Menu:
“Salt =XXXX ppm (X.x g/l)” (
The optimum salt level is 3000 ppm (3.0 g/l)
4500 ppm for maximum chlorine production)
“Add Salt xx Lbs (xx Kg)”
(The amount of salt needed to maintain 3000 ppm (3.0 g/l))
“Temperature XX° F (XX° C)”
(The temperature of the wate
r flow
ing through the Tri-
s
ensor)
“Cell = XX V XX.x A”
(The measured voltage and current sent to the
Pool Pilot
Cell)
“Amp-Hrs = xxxxxx”
(The amount of current times hours of operation received by the
Pool Pilot
Cell) .
This is only viewable if "Tes
t P
ool Pilot
"
was selected under the
"Maintenance Menu."
The display will automatically toggle through the following displays ( or
allows manual control forward and back. While in this feature, pressing MENU will override
the remaining displays and exit back to normal operation):
Test Pool Pilot:
(Diagnostic Menu)
Set Time of Day:
1.
Press
or
until desired hours are displayed; then press SELECT.
2.
Press or
until the desired minutes are displayed; then press SELECT.
(Allows for changes to the time of day displays for time zones or day-light savings.)
Press MENU, press or
until
“Maintenance Menu”
is displayed; then press SELECT.
Press or
for desired selections, followed by SELECT
Once all modifications are complete, press or
until “
Exit Menu Mode
” is displayed; then press SELECT. The menu will also time out af
t
er 20 seconds of no key activity.
Force Reverse:
1.
Press or
until “
Force Reverse
” is displayed; then press SELECT.
3.
“Cell reversing” will display temporarily for 40-seconds.
The “
.
”(period) on the end of 2
nd
line of the display will either appear, or disappear—based on its previous state—to indicate cell power polarity has reversed.
Note: this is a diagnostic tool, only, and should not be used unless a problem is suspected.
(This function activates a reverse cycle, which can be used to verify that the self-cleaning feature is working). After sel
e
cting "Force Reverse" there will be a 40
second
delay before proceeding. During the delay "Cell reversing" will display
.
Continued Next Page...
Set Reverse Time:
1.
Press or
until “
Set Reverse Time
” is displayed; then press SELECT (4-hours is the factory setting).
2.
Press or
until the desired cycle time (2, 4, 8, or 16 hours) is displayed; then press SELECT
.
(Used to program the
Pool Pilot
Cell’s self-cleaning c
y
cle.)
NOTICE
Reduced polarity reversing cycle times will reduce
Pool Pilot
Cell life, and
shoul
d
only be used due to uncontrollable scale formation on the
c
ell.
ALWAYS test and adjust water balance,
before
attempting scale control via
shortening reverse period.
Failure to heed the following may result in equipment damage.