INSTALLATION 

(CONTINUED)

Note: Insure “proper” flow rates.  some two-speed
pumps may  provide insufficient flow on low speed.

Flow Rates Within Normal Range:

„

The manifold can be directly plumbed into the system as shown.

„

If the flow rate for the system is less than 20-gpm (76 L/m), a larger pum

p must be

 installed (or steps taken to improve flow rate).

*One set of 68 mm x 2” metric adapters (#19059) are

included with European Systems.
For other plumbing configurations, please contact the

factory for assistance.

Pump

Filter

Manifold  Assembly

To Pool

Return

FIG-9

Flow Rates Exceeding 100-gpm (379 L/m):

N

OTE

: 5-lb spring bypass check valve must be plumbed

in parallel with the manifold.

STEP-3: 

Tighten the unions by hand for a watertight seal. The manifold will accept a 

PPC1, PPC3, PPC4 or PPC5 

cell; use of any other cell may d

amage the power supply

and the equipment warranty will be voided

.

STEP-4: 

Follow the procedures outlined in the maintenance section o

n

 pa

ge-28

 to

 verify proper operation of the Tri-

sen

sor Flow Switch protection.

STEP-2: 

Install the cell into the manifold with the cell cable terminals at the bottom of the manifold as illustrated in picture 

(

fig 10).

NOTICE

If  the  cell  is  improperly  installed  upside  down,  water  from  rain  or  other 

sources may enter the cable contacts and result in failure of the 

Pool Pilot  

C

ell. 

 

Thi

would void the warrantly.

Failure to heed the following may result in equipment damage.

NOTICE

It is extremely important to verify the safe and proper operation of the

Tri-sensor’s Flow Switch protection device before operating equipment.

Failure to heed the following may result in equipment damage.

NOTICE

To  avoid  over-saturation  conditions  of  your 

spa

,  it  is  suggested  to  locate  the 

cell

 

downstream of all other equipment and on the pool return line only.  For 

applications other than as recommended, contact the factory.

Failure to heed the following may result in equipment damage.

Plumbing the Manifold Assembly:

F

ROM

 P

UMP

T

O

WARNING!

MANIFOLD

 

VERTICAL

Mounting the Control Unit:

Your DIG-220 is suitable for indoor or ou

td

oor mounting. If it is connected to 230 Vac, it must be installed at least 5’ (1.5m) horizontal distance from the pool or spa wall (or 

more

 

if local codes require). It it is connected to 115 Vac, it must be installed at l

e

ast 10’ (3m) horizontal distance from the pool 

 

or spa.

.

The DIG0-220 is designed to mount vertically on a flat surface with the wiring inputs facing downward. The enclosure is 

designed to

 allow heat to dissipate from inside the 

box

 

It is important not to block the top or bottom of the box. Do NOT mount the unit inside a panel or a tightly enclosed area without proper ventilation.

The cover of the DIG-220 is removed from the sides by four thumbscrews so it is advisable to leave adequate space 

on the sides for

 hand access to the thumbscrews.

When selecting a location for installing the DIG-220, please note that the Tri-

s

ensor and 

Pool Pilot  

Cell cables are 12’ (3.6m) long.

Failure to heed the following may result in equipment damage.

NOTICE

Verify that the selected DIG-220 location is close enough to the Manifol

d

 

Assembly so that the Tri-

s

ensor and cell cables will have enough slack 

for

 

service or maintenance procedures.

Continued Next Page...

Plumbing the Manifold Assembly Continued:

FIG-10

Содержание DIG-220

Страница 1: ...0 DIG R13 Owner s Manual Salt Chlorine Generator IMPORTANT Swimming Pool Spa Purification System Read This Manual Before Installing or Operating Installation and Operation This manual covers the insta...

Страница 2: ...Requirements 14 For incoming voltage of 230 Vac 14 For incoming voltage of 115 Vac 15 Connecting DIG 220 to External Equipment 15 Connecting DIG 220 to ExternalTime Clock 15 Connecting DIG 220 to Cont...

Страница 3: ...t Remote 23 Select Minerals 23 Pump Program 1 and2 23 Enable Demo 23 REFERENCE SECTION 24 26 SaltAddition Chart 24 Basic Water Chemistry 24 25 Using the Saturation Index SI 25 26 Part Numbers 26 MAINT...

Страница 4: ...f harsh chemical reactions like red eyes green hair itchy skin or faded swim wear Our product makes it easy to retain a constant level of chlorine purifying the water while making it soft and silky to...

Страница 5: ...e sure to leave your name a complete address and your telephone number Or if you prefer you may FAX us at 877 408 8142 Be certain to provide your full address and a daytime telephone number To Contact...

Страница 6: ...th WARNING All field installed metal components such as rails ladders drains or similar hardware within 10 3 m of the spa or hot tub shall be bonded to the equipment grounding bus with copper conducto...

Страница 7: ...lease Note This quick start section assumes the installer has already programmed the system for specific site parameters has established proper water balance and has pretreated water to 1 3 ppm chlori...

Страница 8: ...ee troubleshooting section on page 21 Check System Light Flashes if the water flow is insufficient under the following circumstances When DIG 220 is not set up to control the water pump uses an Extern...

Страница 9: ...oduction of your DIG 220 Please note the following recommended water chemistry parameters See Basic Water Chemistry on page 24 25 and Using the Saturation Index on page 25 26 for further information c...

Страница 10: ...view for details and diagrams Important Features Patented temperature compensation for chlorine output control Programmable microprocessor control Multi language digital display English Spanish Italia...

Страница 11: ...his manual Determine origination point for control center power feed Directly from a circuit breaker From an external timer or From an electronic controller Determine everything needed for installatio...

Страница 12: ...concentration level The DIG 220 uses this data to determine if conditions are safe for the Pool Pilot Cell to operate the signal read from the temperature sensor allows the automatic temperature comp...

Страница 13: ...device before operating equipment Failure to heed the following may result in equipment damage NOTICE To avoid over saturation conditions of your spa it is suggested to locate the cell downstream of...

Страница 14: ...ontractor perform the electrical connections Failure to heed the following may result in permanent injury or death WARNING Mounting the Control Unit Continued Read the following section complety befor...

Страница 15: ...eed Pump or Two Speed Pump connections Select the diagram that matches your application Wiring diagram also located on inside of cover Connecting DIG 220 to External Time Clock FIG 12 TAB 7 TAB 9 230V...

Страница 16: ...speed when internal time clock program does not have the pump operating on high speed A safety shut off wall switch between the circuit breaker and control box is recommended when the circuit breaker...

Страница 17: ...or available types of tablet or granular chlorine as obtained from pool supply to achieve 1 3 ppm free chlorine 4 Add salt to water test the water for salt level first Adjust to 3000 ppm See salt char...

Страница 18: ...l or whether the system is in Boost or Super Boost mode The Second line of the display shows the current TIME in either 12 or 24 hr mode the TEMPERATURE in either Fahrenheit or Celsius whether the cel...

Страница 19: ...for 24 Hours From the normal operation mode press and release the BOOST button The display will flash Boost 24 hour then Boost hh with the hh actually being the displayed hours remaining in the boost...

Страница 20: ...nce menu 1 Press MENU press or until View Setup is displayed then press SELECT 2 allows manual control forward and back While in this feature pressing MENU The display will automatically toggle throug...

Страница 21: ...The display will automatically toggle through the following displays or allows manual control forward and back While in this feature pressing MENU will override the remaining displays and exit back t...

Страница 22: ...ng is 15 000 gallons The range is 500 to 127 500 gallons 1 000 to 226 000 liters 3 Press or until correct pool size is displayed then press SELECT Programming at Installation NOTE Once determined to b...

Страница 23: ...mote runs pump in order to use this option Pump Program 1 and 2 1 Press or until Pump program X is displayed then press SELECT 2 Press to program the pump press D to Delete the program or SELECT to ex...

Страница 24: ...various columns 1 000 2 000 5 000 10 000 15 000 20 000 25 000 30 000 35 000 40 000 4 000 8 000 18 000 38 000 56 000 76 000 94 000 114 000 132 000 152 000 25 50 125 250 376 501 626 751 876 1 002 11 23...

Страница 25: ...ool with fresh water to dilute Diluting will reduce salt and CYA Check and adjust as needed Please note in some areas there may be higher than recommended calcium levels in the tap water If this level...

Страница 26: ...2 1 12 4 0 Water is perfectly balanced Water Test Results 1 FIG 24 Using the Saturation Index SI Continued APA0003 Tri sensor with integrated cord FIG 29 MANIFOLD UNION w Strainer 19065 Union O Ring...

Страница 27: ...age could occur if the pump activates Failure to heed the following may result in permanent injury or death WARNING Failure to heed the following may result in equipment damage NOTICE If the manifold...

Страница 28: ...ced 4 The Tri sensor can now be pulled out of the Tee Firmly grip theTri Ssnsor assembly this is typically done with a large pair of channel lock pliers Twist the Tri sensor back and forth while simul...

Страница 29: ...maintain water in a balanced condition Water main tained in a scaling condition will shorten cell life and may render the chlorina tor inoperative Damage and or service calls caused by improper water...

Страница 30: ...ed for One speed pump see pg 34 When the Tri sensor indicates that water temperature is below 38 F 4 4 C the Control Unit will override the normal timed program cycle and run the pump 30 minutes minim...

Страница 31: ...zer Cyanuric acid level 5 White Flakes in the Water This occurs when excessive calcium hardness is present Usually due to waterchemistry imbalance Adjust your water chemistry visually inspect Cell for...

Страница 32: ...er generation during this display 16 CHECK SYSTEM Light Flashing Message Displayed Pwr Ctrl Error 15 CHECK SYSTEM Light Flashing Contact the factory for Warranty Status Procedures 14 A small dot walks...

Страница 33: ...d to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential i...

Страница 34: ...34 2737 24th St North St Petersburg FL 33713 727 823 5642...

Отзывы: