Simpool Timer Model
INSTRUCTION AND MAINTENANCE MANUAL
Programmable digital peristaltic pump ENGLISH
ADSP7000722 rev. 1.0 23/02/2017
51/64
Step 3
- Close the front glass
Fig. 15 - Reassembly of the peristaltic tube
5.3 TROUBLESHOOTING
Problem: the pump does not turn on, the LED and display remain off
Solution:
3. Make sure the connection to the electrical network has been set up correctly in accordance with the
information provided on the pump identification plate.
4. The electronic board may be damaged as well: call the support Service.
Problem: the pump works well but it doesn't measure out the product into the swimming pool
Solution:
5. Check the product level.
6. Make sure the foot strainer is not clogged up.
7. Make sure the delivery tube is correctly connected to the check valve, at the injection point of the system.
8. Check the status of the peristaltic tube. If evident malformations are detected, make sure that the material
is compatible with the product being dosed by consulting the chemical compatibility table (
and then go ahead with the replacement.
Problem: liquid leaking from the peristaltic tube
Solution:
3. Make sure the delivery and suction tubes are inserted properly and the ring nuts are well tightened.
4. Check the status of the peristaltic tube. If evident malformations are detected, make sure that the material
is compatible with the product being dosed by consulting the chemical compatibility table (
and then go ahead with the replacement
Problem: the pump is not reporting an alarm, it has reached the dosing time but it is not dosing
Solution:
4. Make sure the switch is not set to OFF.
5. Make sure that the pump is not waiting for the stabilization of the signal coming from the recirculation pump
6. Make sure the dosing time
t.d.1-d.8
has been correctly set (value different from 0');
Problem: the threshold of the inhibiting signal cannot be set correctly (from the In.t entry of the
Solution:
3. Check whether the Inhibiting signal is connected correctly.
4. Call the Support Service;
6.0 Returning material to the After-sales service
The material must be sent back in its packaging with all its original protection devices before the end of the
warranty period.
The system must be clean and the chemical product removed from the tubes.
The manufacturer declines any responsibility regarding damages caused by transportation, if the aforementioned
conditions are not complied with.