Simpool Timer Model
INSTRUCTION AND MAINTENANCE MANUAL
Programmable digital peristaltic pump ENGLISH
ADSP7000722 rev. 1.0 23/02/2017
45/64
▪
n.d.1-d.8:
it allows you to display or set the corresponding dosage starting minutes d.1- d.8 using the
▲
and
▼
keys (range 0-59');
▪
t.d.1-d.8:
it allows you to display or set the corresponding dosage length d.1- d.8 expressed in minutes
using the ▲ and ▼ keys (range 0-60');
To go back to the main
do.C
entry of the Programming Menu, press
Enter
for 3 seconds.
Fig. 9- Dosage time and length setting - Programming
3.3.3 Displaying and Resetting Statistics
From the
StA
entry on the Programming Menu you can access the Pump statistics submenu (see Fig. 10).
Here below is the parameter saved during the pump operation:
▪
The pump's overall operating time
P.d.t
, from 0 to 999 hours, with the following format:
-
h.mm
up to 9 h and 59 m
-
hh.m
up to 99 h and 59 m (minutes expressed in tens)
-
hhh
up to 999 h
To reset each of the above-mentioned fields, just access from the numerical value the
rSt
reset entry with the F
key and from there select
YES
, confirming with
Enter
. You will go back to the
t.F.P.
entry.
Fig. 10 - Statistics Menu
To go back to the Programming Menu press
Enter
for 3 seconds.