Simpool Timer Model
INSTRUCTION AND MAINTENANCE MANUAL
Programmable digital peristaltic pump ENGLISH
ADSP7000722 rev. 1.0 23/02/2017
41/64
3.0 PROGRAMMING
3.1 MAIN FEATURES
F
IG
.
5
-
U
SER
I
NTERFACE
The Increase/Decrease keys allow to change the numerical values and scroll through the lists of options for
all the available menu entries.
The Enter key allows to access and exit from the various entries of the submenus. Pressing the key for 3
seconds allows, from the Initial Menu, to access the Programming Menu and to go back to the Menu one
level up from the main entries on a Menu;
The Function key allows to browse through the Menu entries.
By pressing the key for 3 seconds from the initial page, you can access the User Menu;
T
WO
-
COLOURED
LED
The two-coloured LED displays the following conditions:
▪
Steady green
: the pump is active;
▪
Flashing green
:
the pump is dosing;
▪
Steady red
: the pump is not active;
▪
Flashing red
: there is an alarm;
▪
Steady Orange
: if you are browsing the Programming Menu;
▪
Flashing orange
:
Pump priming in progress;
The switch has three positions:
: the pump is active (ON)
O
: the pump is off (OFF)
: the pump is priming (MOM)
The MOM position is monostable, therefore after setting the switch to MOM, when it is released the
switch automatically goes back to OFF.
The pump doses for 60 seconds at the maximum speed; if the MOM key is pressed again before the
60 seconds elapse, the priming is interrupted.
OPERATION
The Timer model pump measures out chemical products for swimming pool water adjustment according to a daily
or weekly time planning.
The dosage will be carried out every day at the time planned, for the length scheduled (from 1 minute to 60
minutes) at full speed (100% of the actual pump flow rate).
It is possible to condition the dosage from the activation and the stabilization of the recirculation pump inhibiting
signal: the dosage starts when the recirculation pump signal is recognised as active and stabilized, in a
programmable time frame (Inhibiting Signal Waiting Period) subsequent to the dosage planned time. Refer to Fig.
6.
It is possible to programme a maximum of 8 product dosages every day. It is also possible to diversify the planning
every day or to set the same dosage scheme every day.