Fig. 7 - Standard programming from User Menu
Dosage length and time can be modified only if the modification entry On Line in the Settings Menu
has been enabled.
3.3 ADVANCED PROGRAMMING
Here below are the various features of the
Programming Menu
in greater detail.
Every parameter that is changed in the pump programming is saved when you go back to the initial
display. If the pump power supply is disconnected before going to the stand-by display, programmed
data is lost.
3.3.1 Setting the Language
From the
LAn
entry you can choose between Italian
It
and English
En
via the
▲
▼ keys. Use
Enter
to enter and
exit.
(Fig. 8)
Fig. 8 - Setting the Language
3.3.2 Dosage Calendar Programming
From the
do.C
entry it is possible to access the following submenu: (Fig. 9)
▪
Sun/Mon/Tue/Wed/Thu/Fri/Sat
/
ALL
: it allows you to select the days of the week using the
▲
and
▼ keys
and if necessary it allows you to set a daily programming using the "
ALL
" entry;
▪
H.d.1-d.8:
it allows you to display or set the corresponding dosage starting time d.1- d.8 using the
▲
and
▼ keys (range 0-23 h);