8
QUALITY FOR PROFESSIONALS
5.6 Agitator
The two agitators are fitted in the container and are driven
at a constant speed by their own agitator motor.
The motor is located between the two discharge hoppers
and operates the agitator in the spreading tank, which
turns in a vertical direction, via a drive shaft. The agitator
does not have to be switched on separately; it starts
turning as soon as the spreader plates are switched on.
The shape of the agitator (star-shaped) and the vertical
rotation direction avoid the spread material being ground
up.
5.7 Emptying the container
To empty the container, unscrew the two discharge
nozzles at the front of the tank and hold a box, bag
or other bin under it.
TIP: In order to ensure full emptying, use the
calibration bag, which comes as standard.
Then secure the calibration bag in front of the
spreader plates. It is secured by using magnets,
which are sewn into the calibration bag.
Then, you can fully empty the container by selecting the menu item "Empty" on the
control box [see item 6.4 of the selection menu]:
The agitator motor and spreader discs start to turn
slowly and the metering shutter opens fully. Allow
the spreader to run until the container is completely
empty and the unit is no longer discharging spread
material.
IMPORTANT NOTE: Please do not clean the spreader with water. Only clean the ZS
200 M4 with an air pistol (blow it out) or with a dry or slightly dampened cloth.
Fig.: 8
Fig.: 7
Fig.: 9