CHAPTER 2 DECADE II DCC upgrade kit install guide, edition 5
21
Figure 10 Releasing contact 4 (with thick orange wire) from kk Molex
connector 7 using a flat screw driver.
Remove contact 4 attached to the thick orange wire as depicted in figure 10.
Use a flat screwdriver to unlock the contact from the plastic housing.
Unlocking is achieved by inserting the screw driver in the slit, and gentle
pushing the metal contact while simultaneously pulling the wire out of the
housing.
Figure 11 Connector 7 with new wire configuration for analog heater control
(left-side). For reference the old wire configuration is shown on the right-side.
Subsequently insert the contact in position 1 of connector 7 as depicted in
figure 11. Make sure that the contact is firmly locked into the plastic housing
and insert the connector back into the corresponding socket on the control
board.