112
Release:
2017
CyBio
®
Well
vario
Fault
Removal
Sum
of
volumes
too
great
The
sum
of
all
volumes
aspirated
and
dispensed
is
too
great.
Valid
values
are
within
the
range
of
2
μ
l
to
250
μ
l.
On
adding
all
signed
cycle
values
up
with
each
other,
this
range
must
not
be
exceeded.
Correct
setting
values
appropriately.
Sum
of
volumes
before
and
after
block
is
unequal
zero
The
sum
of
volumes
aspi-
rated
and
ejected
in
a
cur-
rent
block
(program,
combined
commands,
repeat
modules)
is
unequal
zero.
On
adding
all
cycle
values
up
with
each
other,
their
sum
must
equal
zero
within
a
given
block.
Correct
setting
values
appropriately.
Text
too
long
Text
which
is
intended
for
output
to
the
system
dis-
play
is
too
long.
Shorten
output
text.
Table
reached
upper
end
position
Table
motion
has
reached
its
upper
end
position.
Use
keyboard
at
the
CyBio
®
Well
vario
to
trig-
ger
table
motion
into
low-
ermost
position.
To
do
this,
press
both
direction
keys
at
the
same
time.
This
will
automatically
trigger
a
drive
calibration
routine.
Table
reached
lower
end
position
Table
motion
has
reached
its
lower
end
position.
Use
keyboard
at
the
CyBio
®
Well
vario
to
trig-
ger
table
motion
into
low-
ermost
position.
To
do
this,
press
both
direction
keys
at
the
same
time.
This
will
automatically
trigger
a
drive
calibration
routine.
Unknown
keyboard
code
The
code
of
a
key
which
was
pressed
at
the
system
control
panel
is
unknown
to
software.
This
error
occurs
following
an
attempt
to
trigger
a
pro-
gram
file
that
was
created
using
a
more
recent
than
the
currently
installed
soft-
ware
version.
Use
latest
software
version
in
this
case.
If
this
can
be
discarded
as
potential
error
cause,
the
particular
file
is
likely
to
have
suf-
fered
damage.
Create
a
new
program
file.
Error message
Cause
Action for removal
Содержание CyBio Well vario OL3381-25-300
Страница 1: ...Operating Manual CyBio Well vario...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 7: ......
Страница 8: ......
Страница 16: ...XVI Release 2017 CyBio Well vario...
Страница 26: ...10 Release 2017 CyBio Well vario Technical Specifications...
Страница 60: ...44 Release 2017 CyBio Well vario Technical Description...
Страница 74: ...58 Release 2017 CyBio Well vario Initial Start Up Routine Start Up Procedure...
Страница 138: ...122 Release 2017 CyBio Well vario Maintenance Care...
Страница 144: ...128 Release 2017 CyBio Well vario Accessories Spare Parts...
Страница 146: ...130 Release 2017 CyBio Well vario Waste Disposal...
Страница 148: ...132 Release 2017 CyBio Well vario...
Страница 158: ...142 Release 2017 CyBio Well vario...
Страница 160: ...144 Release 2017 CyBio Well vario...
Страница 164: ...148 Release 2017 CyBio Well vario...