ADT7476
Rev. B | Page 53 of 72
REGISTER TABLES
Table 18. ADT7476 Registers
Address R/W Description
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Default Lockable
0x10 R/W
Configuration
Register 6
Extra
Slow
V
CCP
Low
MasterEn SlaveEn THERM in
Manual
SLOW
Remote 2
SLOW
Local
SLOW Remote 1
0x00
Yes
0x11 R/W
Configuration
Register 7
RES RES
RES RES
RES
RES
RES
DisTHERMHys
0x00 Yes
0x20 R 2.5
V
Measurement
9
8
7 6
5 4 3 2
0x00
0x21 R V
CCP
Measurement
9
8
7 6
5 4 3 2
0x00
0x22 R V
CC
Measurement
9
8
7 6
5 4 3 2
0x00
0x23 R 5
V
Measurement
9
8
7 6
5 4 3 2
0x00
0x24 R 12
V
Measurement
9
8
7 6
5 4 3 2
0x00
0x25 R Remote
1
Temperature
9
8
7 6
5 4 3 2
0x80
0x26 R Local
Temperature
9
8
7 6
5 4 3 2
0x80
0x27 R Remote
2
Temperature
9
8
7 6
5 4 3 2
0x80
0x28 R TACH1
Low
Byte
7
6
5 4
3 2 1 0
0x00
0x29 R TACH1
High
Byte
15 14
13 12
11
10
9
8
0x00
0x2A R TACH2
Low
Byte
7
6
5 4
3 2 1 0
0x00
0x2B R TACH2
High
Byte
15 14
13 12
11
10
9
8
0x00
0x2C R TACH3
Low
Byte
7
6
5 4
3 2 1 0
0x00
0x2D R TACH3
High
Byte
15 14
13 12
11
10
9
8
0x00
0x2E R TACH4
Low
Byte
7
6
5 4
3 2 1 0
0x00
0x2F R TACH4
High
Byte
15 14
13 12
11
10
9
8
0x00
0x30 R/W
PWM1
Current
Duty Cycle
7
6
5 4
3 2 1 0
0xFF
0x31 R/W
PWM2
Current
Duty Cycle
7
6
5 4
3 2 1 0
0xFF
0x32 R/W
PWM3
Current
Duty Cycle
7
6
5 4
3 2 1 0
0xFF
0x38 R/W
PWM1
Max
Duty Cycle
7
6
5 4
3 2 1 0
0xFF
Yes
0x39 R/W
PWM2
Max
Duty Cycle
7
6
5 4
3 2 1 0
0xFF
Yes
0x3A R/W
PWM3
Max
Duty Cycle
7
6
5 4
3 2 1 0
0xFF
Yes
0x3D R Device
ID
Register
7
6
5 4
3 2 1 0
0x76
0x3E R Company
ID
Number
7
6
5 4
3 2 1 0
0x41
0x40 R/W
Configuration
Register 1
VCORE_
LOW_
ENABLE
TODIS FSPDIS
Vx1
FSPD
RDY
LOCK
STRT
0x04 Yes
0x41
R
Interrupt Status
Register 1
OOL R2T LT
R1T 5
V
V
CC
V
CCP
2.5 V/THERM
0x00
www.BDTIC.com/ADI