August 2012
L010796
39
^ - Number of Outputs During Output on the Fly
Format:
^[value]
Description: This command sets the number of times output 1 will turn on during an output
on the fly move. This command is used in conjunction with the output on the fly enabled “(“
command.
Range:
0 - 255
{ - Analog Position Lower Limit
Format:
{[value]
Description: This command sets the lower limit that is used during the calculation follow-
ing a P command for the analog position input. This command is used in conjunction with
the analog position enable “:” and absolute position “P” commands.
Range:
0 - 65535
} - Analog Position Upper Limit
Format:
}[value]
Description: This command sets the upper limit that is used during the calculation follow-
ing a P command for the analog position input. This command is used in conjunction with
the analog position enable “:” and absolute position “P” commands.
Range:
0 - 65535
~ - Set Address Register
Format:
~[value]
(No address is needed before this function. @ ~[value] will set
the
address)
Description: This command sets the address for communication inside the DPE25611.
Range:
0 - 99
July 2018