Initial Configuration and Firmware Upgrade
22
NI Series WebConsole & Programming Guide
3.
Click
Done
to close the
Device Addressing
dialog.
4.
Click
Reboot
(from the
Tools > Reboot the Master Controller
dialog) and wait for the System
Master to reboot.
The STATUS and OUTPUT LEDs should begin to alternately blink during the incorporation. Wait
until the STATUS LED is the only LED to blink.
5.
Press
Done
once until the
Master Reboot Status
field reads *
Reboot of System Complete*
.
6.
Click the
OnLine Tree
tab in the Workspace window to view the devices on the System.
The default System value is one (1).
7.
Right-click the associated System number (
or anywhere within the tab itself
) and select
Refresh
System
. This establishes a new connection to the specified System and populates the list with
devices on that system.
8.
Use
Ctrl
+
S
to save these changes to your NetLinx Project.
By setting the system to its default value (#1), Modero panels that were set to
connect to the Master on another System value will not appear in the
OnLine Tree
tab of the Workspace window.
For example: A Modero touch panel was previously set to System #2. The system is
then reset to its default setting of System #1 and then refreshed from within the
Workspace window. The panel will not reappear until the system is changed (from
within the System Connection page on the Modero) to match the new value and both
the Master and panel are rebooted.
Содержание NetLinx Master-Ethernet Card/Module NXC-ME260
Страница 8: ...vi NI Series WebConsole Programming Guide Table of Contents ...
Страница 12: ...Overview 4 NI Series WebConsole Programming Guide FIG 1 Internet Explorer with BonJour plug in ...
Страница 13: ...Overview 5 NI Series WebConsole Programming Guide ...
Страница 14: ...Overview 6 NI Series WebConsole Programming Guide ...
Страница 34: ...Onboard WebConsole User Interface 26 NI Series WebConsole Programming Guide ...
Страница 36: ...WebConsole WebControl Options 28 NI Series WebConsole Programming Guide ...
Страница 88: ...WebConsole System Options 80 NI Series WebConsole Programming Guide ...
Страница 104: ...Programming 96 NI Series WebConsole Programming Guide ...
Страница 156: ...Appendix A IPSec Configuration File 148 NI Series WebConsole Programming Guide ...
Страница 161: ...Terminal Program Port Telnet Commands 153 NI Series WebConsole Programming Guide ...