Initial Configuration and Firmware Upgrade
20
NI Series WebConsole & Programming Guide
4.
After the Communication Verification dialog window verifies active communication between the
PC and the NI unit, verify the NetLinx NXC Control Cards appear in the
OnLine Tree
tab of the
Workspace window (FIG. 10).
5.
If the NXC card firmware being used is not current, download the firmware file by first logging in to
www.amx.com
and then navigate to
Tech Center
>
Firmware Files
and from within the NetLinx
section of the web page locate the NXC card
entries.
6.
Click on the desired Kit file link and after you’ve accepted the Licensing Agreement, verify you
have downloaded the NetLinx NXC card firmware (Kit) file to a known location.
7.
Verify you have downloaded the latest NetLinx Control Card firmware (Kit) file to a known
location.
8.
Select
Tools
>
Firmware Transfers > Send to NetLinx Device
from the Main menu to open the
Send to NetLinx Device dialog (FIG. 11). Verify the target’s
Device and System
numbers matches
the value listed within the System folder in the Workspace window.
9.
Select the Control Card’s Kit file from the
Files
section (FIG. 11) (
in our above example we chose
to update the NXC-VOL4 card
).
10.
Enter the
System
and
Device
numbers associated with the desired Master (
listed
in the Workspace
window
).
A device
value of
00003
is the same as a value of
3
.
11.
Click the
Reboot Device
checkbox to reboot the NI unit after the firmware update process is
complete and then re-detect the new NXC card firmware.
12.
Click
Send
to begin the transfer. The file transfer progress is indicated on the bottom-right of the
dialog (FIG. 11).
13.
Click
Close
once the download process is complete.
14.
Click
Reboot
(from the
Tools > Reboot the Master Controller dialog
) and wait for the System
Master to reboot.
The STATUS and OUTPUT LEDs should begin to alternately blink during the incorporation. Wait
until the STATUS LED is the only LED to blink.
FIG. 10
Sample NetLinx Workspace window (showing OnLine Tree tab)
On-board NI Master
Control cards (
NI-4x00 ONLY
)
NetLinx Integrated Controller
NetLinx Studio version
If the control card firmware is not up to date; download the latest firmware file from
www.amx.com
>
Tech Center
>
Downloadable Files
>
Firmware Files
>
NXC-XXX.
In this example, the NXC-VOL card contains out-of-date firmware and requires build
1.00.09.
Содержание NetLinx Master-Ethernet Card/Module NXC-ME260
Страница 8: ...vi NI Series WebConsole Programming Guide Table of Contents ...
Страница 12: ...Overview 4 NI Series WebConsole Programming Guide FIG 1 Internet Explorer with BonJour plug in ...
Страница 13: ...Overview 5 NI Series WebConsole Programming Guide ...
Страница 14: ...Overview 6 NI Series WebConsole Programming Guide ...
Страница 34: ...Onboard WebConsole User Interface 26 NI Series WebConsole Programming Guide ...
Страница 36: ...WebConsole WebControl Options 28 NI Series WebConsole Programming Guide ...
Страница 88: ...WebConsole System Options 80 NI Series WebConsole Programming Guide ...
Страница 104: ...Programming 96 NI Series WebConsole Programming Guide ...
Страница 156: ...Appendix A IPSec Configuration File 148 NI Series WebConsole Programming Guide ...
Страница 161: ...Terminal Program Port Telnet Commands 153 NI Series WebConsole Programming Guide ...