Initial Configuration and Firmware Upgrade
13
NI Series WebConsole & Programming Guide
3.
Click the
Communications Settings
button to open the Communications Settings dialog.
4.
Click on the
NetLinx Master
radio button (
from the Platform Selection section
) to indicate you are
working with a NetLinx Master (such as the NXC-ME260/64 or NI-Series of Integrated
Controllers).
5.
Click on the
TCP/IP
radio button (
from the Transport Connection Option section
) to indicate you
are connecting to the Master via an IP Address.
6.
Click the
Edit Settings
button (
on the Communications Settings dialog
) to open the TCP/IP
Settings dialog (FIG. 5). This dialog contains a series of previously entered IP Address/URLs and
their associated names, all of which are stored within Studio and are user-editable.
7.
Click the
New
button to open the New TCP/IP Settings dialog where you can enter both a
previously obtained DHCP or Static IP Address and an associated description for the connection
into their respective fields.
8.
Place a checkmark within the
Automatically Ping the Master Controller to ensure availability
radio
box to make sure the Master is initially responding online before establishing full communication.
9.
Click
OK
to close the current New TCP/IP Settings dialog and return to the previous TCP/IP
Settings dialog where you must locate your new entry within the List of Addresses section.
10.
Click the
Select
button to make that the currently used IP Address communication parameter.
11.
Click
OK
to return to the Communications Settings dialog and place a checkmark within the
Authentication Required
radio box if your Master has been previously secured with a username/
password.
12.
Click on the
Authentication Required
radio box (if the Master is secured) and then press the
User
Name and Password
button to open the
Master Controller User Name and Password
dialog.
13.
Within this dialog, you must enter a previously configured username and password (with sufficient
rights) before being able to successfully connect to the Master.
14.
Click
OK
to save your newly entered information and return to the previous Communication
Settings dialog where you must click
OK
again to begin the communication process to your Master.
15.
Click
Yes
to interrupt the current communication from the Master and apply the new settings.
16.
Once the particular System Master is configured for communication via an IP Address, remove the
DB9 connector from the Program port on the NI on-board Master.
17.
Click
Reboot
(from the
Tools > Reboot the Master Controller dialog
) and wait for the Master to
reboot.
The STATUS and OUTPUT LEDs should begin to alternately blink during the incorporation. Wait
until the STATUS LED is the only LED to blink.
18.
Press
Done
once until the
Master Reboot Status
field reads *
Reboot of System Complete*
.
19.
Click the
OnLine Tree
tab in the Workspace window to view the devices on the System.
The default
System value is one (1)
.
20.
Right-click the associated System number and select
Refresh System
. This establishes a new
connection to the specified System and populates the list with devices on that system.
The
communication method is then highlighted in green on the bottom of the NetLinx Studio window.
If you are currently connected to the assigned Master, a popup asks whether you
would want to temporarily stop communication to the Master and apply the new
settings.
Содержание NetLinx Master-Ethernet Card/Module NXC-ME260
Страница 8: ...vi NI Series WebConsole Programming Guide Table of Contents ...
Страница 12: ...Overview 4 NI Series WebConsole Programming Guide FIG 1 Internet Explorer with BonJour plug in ...
Страница 13: ...Overview 5 NI Series WebConsole Programming Guide ...
Страница 14: ...Overview 6 NI Series WebConsole Programming Guide ...
Страница 34: ...Onboard WebConsole User Interface 26 NI Series WebConsole Programming Guide ...
Страница 36: ...WebConsole WebControl Options 28 NI Series WebConsole Programming Guide ...
Страница 88: ...WebConsole System Options 80 NI Series WebConsole Programming Guide ...
Страница 104: ...Programming 96 NI Series WebConsole Programming Guide ...
Страница 156: ...Appendix A IPSec Configuration File 148 NI Series WebConsole Programming Guide ...
Страница 161: ...Terminal Program Port Telnet Commands 153 NI Series WebConsole Programming Guide ...