AM8a Instruction Manual
(18-0037)
Meter Display
0037-S06.L_43
February 10, 2000
6-11
6.6
E & M and SF – ANALOG MEASURE
The measurements described in sub-sections 6.6.1 through 6.6.7 are made at the
PCM1
jacks
labeled
TX/2W
and
RX
, and the
PCM2
jacks labeled
TX
or
RX
on the front panel. Use as many
48-0047, or 48-0048 cables as are needed. The
MEASURE
selections described are listed in
the order presented (beginning at top of left column) as the
MENU
up key is pressed:
Description of Measurements
TX1 Vcm dc
TX1 Vcm ac
PCM1 Transmit tip & ring common mode
RX1 dBdsx
PCM1 Received tip-ring bipolar amplitude
RX1 Vcm dc
RX1 Vcm ac
PCM1 Receive tip & ring common mode
TX2 Vcm dc
TX2 Vcm ac
PCM2 Transmit tip & ring common mode
RX2 dBdsx
PCM2 Received tip-ring bipolar amplitude
RX2 Vcm dc
RX2 Vcm ac
PCM2 Receive tip & ring common mode
TX1 Tone
PCM1 Transmit CHANnel tone (DBm and Hz)
RX1 Tone
PCM1 Receive CHANnel tone (DBm and Hz)
TX2 Tone
PCM2 Transmit CHANnel tone (DBm and Hz)
RX2 Tone
PCM2 Receive CHANnel tone (DBm and Hz)
6.6.1
TX1 Vcm or TX2 Vcm, dc or ac:
These selections measure the voltage difference or
delta between the Tip and Ring leads (
∆
V) of the
PCM1 TX
or
PCM2 TX
input jack. The
differential voltage measured is referenced to CO ground which can be connected to a
binding post on the rear of the unit.
6.6.2
RX1 Vcm or RX2 Vcm, dc or ac:
These selections measure the voltage difference or
delta between the Tip and Ring leads (
∆
V) of the
PCM1 RX
or
PCM2 RX
input jack. The
differential voltage measured is referenced to earth ground rather than CO ground. The
differential voltage measured is referenced to CO ground which can be connected to a
binding post on the rear of the unit.
6.6.3
TX1 Tone or TX2 Tone:
These selections are used to measure Level and Frequency of
Tones present on the selected channel of the
PCM1 TX
or
PCM2 TX
input jack. The
Level is displayed in dBm and the frequency is displayed in Hz. A measured value of
"
UNDER
" in the Level display indicates the measurement is lower than the acceptable
limit. (dBm < -40).
Содержание AM8a
Страница 1: ...MODEL AM8a PCM VF CALL ANALYZER INSTRUCTION MANUAL...
Страница 13: ...Table of Contents 18 0037 AM8a Instruction Manual February 10 2000 0037 TOC L_ xii...
Страница 17: ...Table of Contents 18 0037 AM8a Instruction Manual February 10 2000 0037 TOC L_ xvi...
Страница 35: ...Front Panel Operation 18 0037 AM8a Instruction Manual February 10 2000 0037 S01 L_ 1 18...
Страница 55: ...Emulation Parameters 18 0037 AM8a Instruction Manual February 10 2000 0037 S03 L_ 3 8...
Страница 65: ...Analysis Parameters 18 0037 AM8a Instruction Manual February 10 2000 0037 S04 L_ 4 10...
Страница 69: ...Auto and Manual Dialing 18 0037 AM8a Instruction Manual February 10 2000 0037 S05 L_ 5 4...
Страница 89: ...Meter Display 18 0037 AM8a Instruction Manual February 10 2000 0037 S06 L_ 6 20...
Страница 115: ...RS232 Entries and Printouts 18 0037 AM8a Instruction Manual February 10 2000 0037 S07 L_ 7 26...
Страница 125: ...Technical Specifications 18 0037 AM8a Instruction Manual February 10 2000 0037 S08 L_ 8 10...
Страница 151: ...Index 18 0037 AM8a Instruction Manual February 10 2000 0037 IDX L_ I 14 Y Yellow 6 14 Z ZCS 2 5 Zero Sup 2 4...