Configuration Parameters
(18-0037)
AM8a Instruction Manual
February 10, 2000
0037-S02.L_
2-4
rpt 2 to 1:
is used during Drop & Insert testing. This mode will allow the selected
CHAN
nel to be used for emulation towards the equipment connected to the
PCM2
input
jacks; other channels are uninterrupted to
PCM1
.
NOTE:
In
MONITOR
mode all channels pass from
PCM1
to
PCM2
when
rpt 1 to 2
or
rpt 2 to 1
are selected. See Section 6 for metering the a and b bits to find an
idle channel that can be selected for drop and insert testing.
In Drop & Insert testing, the equipment which supplies the "Master" clock
for framing must be connected to the
PCM1
input jack.
2.3.2
FRAMING:
This parameter selects the span framing type assignment that the AM8a can
emulate and monitor.
D3/D4:
is the most popular type of framing. It uses 12 separate frames in a super-
frame. The signaling bits are identified as "a" and "b" bits.
ESF:
Extended SuperFrame is another popular type of framing. This type uses 24
frames rather than 12 frames. Its signaling bits are" a, b, c, and d".
SLC®96 I:
(
SLC® 96 Mode I
) monitors 96 channels or data link on four spans (A, B, C,
and D). Assignment of channels to time-slots is fixed. Refer to Table 6-5 for these
assignments.
SLC®96 II:
(
SLC®96 Mode II
) monitors 96 channels or data link on two spans (A and C).
Assignment of channels to time-slots is on as-available basis. Refer to 2.5.4 for use of
activity message to determine line groups and active channels.
NOTE:
SLC®96 I
and
SLC®96 II
can only be used in monitor mode.
2.3.3
ZERO SUP:
Zero Suppression is the way that the AM8a handles a data pattern of all
"0's" during transmission.
AMI:
(Alternate Mark Inversion) is the standard protocol for T1 spans.
AMI
does not
supply any zero suppression conversions.
B8ZS:
(Binary Eight Zero Suppression) will insert two bipolar violations when eight
consecutive zeros are encountered. The receiving equipment will recognize this and
remove the BPV's and correctly interpret the data.
Содержание AM8a
Страница 1: ...MODEL AM8a PCM VF CALL ANALYZER INSTRUCTION MANUAL...
Страница 13: ...Table of Contents 18 0037 AM8a Instruction Manual February 10 2000 0037 TOC L_ xii...
Страница 17: ...Table of Contents 18 0037 AM8a Instruction Manual February 10 2000 0037 TOC L_ xvi...
Страница 35: ...Front Panel Operation 18 0037 AM8a Instruction Manual February 10 2000 0037 S01 L_ 1 18...
Страница 55: ...Emulation Parameters 18 0037 AM8a Instruction Manual February 10 2000 0037 S03 L_ 3 8...
Страница 65: ...Analysis Parameters 18 0037 AM8a Instruction Manual February 10 2000 0037 S04 L_ 4 10...
Страница 69: ...Auto and Manual Dialing 18 0037 AM8a Instruction Manual February 10 2000 0037 S05 L_ 5 4...
Страница 89: ...Meter Display 18 0037 AM8a Instruction Manual February 10 2000 0037 S06 L_ 6 20...
Страница 115: ...RS232 Entries and Printouts 18 0037 AM8a Instruction Manual February 10 2000 0037 S07 L_ 7 26...
Страница 125: ...Technical Specifications 18 0037 AM8a Instruction Manual February 10 2000 0037 S08 L_ 8 10...
Страница 151: ...Index 18 0037 AM8a Instruction Manual February 10 2000 0037 IDX L_ I 14 Y Yellow 6 14 Z ZCS 2 5 Zero Sup 2 4...