33
© American Time
AllSync IQ Installation Manual
Glossary
Appendix
Troubleshooting
Installation
Intr
oduction
Settings & Configuration
The Config Menu offers the ability to change several settings for the AllSync IQ Master.
Press
P6
and enter your service lock to access the Configuration Menu.
w
Manage Locks: From Config Menu press
1
•
a. User Lock. Press:
1
and enter a new 4 digit User Lock OR
Press 0000 to disable this feature.
User Lock
• Press
O
n
Note:
User Lock is the user security level used for accessing time/date
and event menus.
•
b. Service Lock. Press:
2
and enter a new 4 digit Service
Lock or enter 0000 to disable this feature.
Service Lock:
• Press
O
n
Note:
Service Lock is the service security level used for accessing
System Controller configuration menus.
x
Time Sync Priority: From the Config Menu press
2
This feature is used to determine the priority of time synchronization of
the System Controller. This screen only displays the sync options that your
System Controller supports.
•
a. Press the number that corresponds to your time sync
priority
•
b. Enter the minutes and seconds that the System Controller should
attempt to synchronize each hour to the time sync option chosen.
y
Clock Code: From the Config Menu press
3
This feature is used to set the clock code for wired clock circuits.
•
a. Enter the clock code using the keypad
•
b. Press
O
z
Clear/Restore: From the Config Menu press
4
This feature allows for the deletion of all events or restoration of the
System Controller to factory defaults.
• a. Press
2
to delete all events or
0
to cancel.
• b. Press
1
to restore factory defaults or
0
to cancel.
Config Menu
Time Sync Priority
2=Ethernet
Ok=Done
Config Menu
Time Sync Priority
Set to Ethernet
At 04:15
OK=Done
Config Menu
Clear All Events
1=Confirm
0=Cancel
Config Menu
Restore Factory
Settings
1=Confirm 0=Cancel
Config Menu
Choose Service Lock:
xxxx
0000=Disable OK=Done
Config Menu
Choose User Lock:
xxxx
0000=Disable OK=Done
4a
4b
6a
6b
Config Menu
Select Clock Code
01
OK=Done
5
3b
3a