50
C. FIXED PARAMETERS
1.
Spin Time (“
SPIN TIME
”) is fixed at 2-1/2 minutes in forward and 2 minutes in reverse.
2.
Stop (Dwell) Time (“
STOP TIME
”) is fixed at 7 seconds (in the Auto Mode) and is not adjustable.
SECTION VIII
PHASE 7 OPL PROGRAMMING LIMITS
A. PREPROGRAMMED CYCLES
1.
Automatic Cycle (Mode) (
Patent No. 4,827,627
)
a.
Drying Temperature from 160ºF to 200ºF in one-degree increments.
b.
Dryness Level (percentage of dryness from 90% to 100% in one-percent increments.
c.
Cool Down Time from 0 to 99 minutes in one-minute increments.
d.
Cool Down Temperature from 70ºF to 100ºF in one-degree increments.
2.
Timed (Manual) Drying Cycle (Mode)
a.
Drying Temperature from 100ºF to 200ºF in one-degree increments.
b.
Drying Time from 0 to 99 minutes in one-minute increments.
c.
Cool Down Time from 0 to 99 minutes in one-minute increments for preprogrammed cycle.
d.
Cool Down Temperature from 70ºF to 100ºF in one-degree increments.
e.
Reversing Models
1) Automatic Cycle (
Patent No. 4,827,627
) Spin time and Stop time
is not
programmable.
Refer to
Fixed Parameters
on
part C.
2) Timed Cycle
a) Spin Time (“
SPIN TIME
”) from 30 seconds to 120 seconds in one-second increments.
b) Stop (Dwell) Time (“
STOP TIME
”) from 7 seconds to 10 seconds in one-second
increments.
B. SYSTEM PARAMETERS (Program Locations)
1.
Factor “A”
(Slope) from 1 to 9 in increments of one (1).
2.
Factor “B”
(Heat Loss - Offset) from 1 to 99 in increments of one (1).
3.
Manual Selection Auto Mode (“COOL DOWN TIME”) from 0 to 99 minutes in one-minute increments.
4.
Audio Alert 0-10.
5.
Lint Count 1-5.