36
3: PROGRAM 0 - 99 CYCLE
SELECT 0 - 99 CYCLE
**
(“**” DISPLAY THE NUMBER CHOSEN. DEFAULTS TO “0”)
SELECT CYCLE TYPE
*
(“*” DISPLAY THE CYCLE TYPE “AUTO” OR “MANUAL”)
AUTO
0: REVERSE MODE
ON
OFF
1: ENTER DRY TEMP 160 TO 200 F
*** F
(“***” = THE DEFAULT DRY TEMP FOR THAT CYCLE)
2: ENTER DRY LEVEL 90 TO 100 %
*** %
(“***” = THE DEFAULT DRY LEVEL FOR THAT CYCLE)
3: ENTER COOL DOWN TIME 0 TO 99 MINUTES
** MIN
(“***” = THE DEFAULT TIME FOR THAT CYCLE)
4: ENTER COOL DOWN TEMP 70 TO 100 F
*** F
(“***” = THE DEFAULT TEMP FOR THAT CYCLE)
5: ENTER ‘A’ FACTOR 1 TO 9
A = 5
(5 = DEFAULT VALUE)
6: ENTER ‘B’ FACTOR 1 TO 99
B = 78
(78 = DEFAULT VALUE)
MANUAL
0: REVERSE MODE
ON
OFF
1: ENTER DRY TIME 0 TO 99 MINUTES
** MIN
(“**” = THE DEFAULT MINUTES FOR THAT CYCLE)
2: ENTER DRY TEMP 100 TO 200 F
*** F
(“***” = THE DEFAULT DRY TEMP FOR THAT CYCLE)
3: ENTER COOL DOWN TIME 0 TO 99 MINUTES
** MIN
(“**” = THE DEFAULT TIME FOR THAT CYCLE)
4: ENTER COOL DOWN TEMP 70 TO 100 F
*** F
(“***” = THE DEFAULT TEMP FOR THAT CYCLE)
5: ENTER SPIN TIME 30 TO 120 SECONDS
*** SEC (“***” = THE DEFAULT TIME FOR THAT CYCLE)
6: ENTER STOP TIME 7 TO 10 SECONDS
*** SEC (“***” = THE DEFAULT TIME FOR THAT CYCLE)