23
NOTE:
The dryer can be stopped at any time by pressing the “CLEAR/STOP” Key. If the temperature
is above the Cool Down setpoint when the “CLEAR/STOP” is pressed, then it will go into a
Cool Down cycle. If the “CLEAR/STOP” key is pressed again at this point the cycle that
was in progress
will be cancelled
and returned to the “READY” state. If the temperature is
below the Cool Down set point. The cycle that was in progress
will be cancelled
, and go to the
Wrinkle Guard.
7)
Once the preprogrammed percentage of extraction (dryness level) is reached, the drying cycle will end,
and the Cool Down Cycle will begin.
8)
Once the COOL DOWN Cycle begins at the end of the heat cycle the L.E.D. display will read COOL
DOWN TEMP ___/___MINUTES REMAINING. At the end of the heat cycle the dryer will shut off
the heat, and continue the Fan and Tumbler until the Cool Down time, or temperature is reached.
9)
Once the COOL DOWN cycle is completed the Phase 7 OPL microprocessor
controller (computer) will proceed into the Wrinkle Guard cycle. The Audio Alert tone will sound (for
amount set in Audio Alert ON time). The L.E.D. display will read “WRINKLE GUARD”. The times are
fixed at 2 minutes OFF, 2 minutes ON for a max time of 99 minutes. These times are not programmable.
During the ON time, the Blower (fan) and the basket (tumbler) will start to rotate (without heat for 2
minutes). The Phase 7OPL microprocessor controller (computer) will repeat this process until the
Maximum Wrinkle Guard On Time has expired (99 minutes). The L.E.D. display will then read “CYCLE
DONE” and lockout the dryer functions until the doors are opened. It will then return to “READY”.
NOTE
: Mechanical functions of the dryer are not allowed during the ON time. The Blower (fan)
must be OFF to perform mechanical functions. However the “CLEAR/STOP” key
may be pressed at any time to end the Wrinkle Guard cycle. Mechanical functions of the
dryer are allowed during the OFF time.
b. Timed (Manual) Dryer Cycle
1) L.E.D. display reads “READY” (no cycle in progress).
2) Press Key MAN
3) L.E.D. display will now read “ENTER DRY TIME 0 TO 99 MINUTES” (Defaults to 0). i.e.,
for 40 minutes, press Key “4”, Key “0”, and then press the “ENTER/START” Key
to accept the value.
4) L.E.D. display will now read “ENTER DRY TEMP __ TO __” (Default 100
°F or 37°C)
Enter the temperature desired (from
100ºF to 200ºF in one-degree increments or from 37ºC
to 93ºC in one-degree increments). i.e., for 182 ºF, press Key “1”, Key “8”, Key “2”, and then
press the “ENTER/START” Key to accept the value.
5) L.E.D. display will now read “ENTER COOL DOWN TIME 0 TO 99 MINUTES”.i.e., for 10
minutes, press Key “1”, Key “0”, and then press the “ENTER/START” Key to accept
the value.
6) L.E.D. display will now read “SELECT REVERSE MODE” (Default to ON). The ON/OFF
selection can be toggled with the UP & DOWN ARROWS. Once selected, press the “ENTER/
START” Key to accept selection.