10
D. TIMED (MANUAL) DRYING CYCLE OPERATION (Mode)
This drying cycle is intended for special loads where a specific amount of drying time and cooling time is
needed, especially for fine, delicate items which require very low temperatures and long drying and/or cool
down time periods.
All the parameters set in “COOL DOWN SETUP” pertain to the Manually loaded Manual and Auto
cycles. The (A-F) and (0-99) cycles that have been selected to be Manual, have separate settings for all the
parameters contained in the “COOL DOWN SETUP” menu
Timed (Manual) Cycle (Mode) Selections:
1) Drying Time - programmable from 0 to 99 minutes in one-minute increments.
2) Cool Down Time - programmable from 0-99 minutes in one-minute increments.
3) Drying Temperature - programmable from 100°F to 200°F in one-degree increments or from 37°C
to 93°C in one-degree increments.
4) For optional reversing, the Phase 7 OPL microprocessor controller can be programmed to reverse or no
reverse (single detection rotation). This is done in “DRYER SETUP”.
5) Wrinkle Guard is always active.