1.2 Safe Handling Guidelines (continued)
1.2.2 Prevent Debris From Entering the Unit
While mounting devices, be sure that all debris (metal chips, wire strands, tapping liq-
uids, etc.) is prevented from falling into the unit, specifically into the M12 connectors.
Debris may cause damage to the unit or unintended machine operation with possible
personal injury.
1.2.3 Remove Power Before Servicing
Remove power before removing or installing any SMD17K units.
1.3 Operating Temperature Guidelines
Due to the onboard electronics, the maximum operating temperature of the SMD17K is limited to 203°F/
95°C. Depending on the operating current setting, move profiles, idle time, and the idle current reduction set-
ting, it is possible to exceed this temperature in a thermally isolated environment. As explained in the mount-
ing section, mounting the SMD17K to a large metal heatsink is the best way to limit the operating
temperature of the device. Operating temperature should be monitored during system startup to verify that the
maximum motor temperature remains below this 203°F/95°C specification. The motor is rated to 266°F/
130°C, but the operating temperature of the device as a whole should be limited to 203°F/95°C. SMD17K
devices have an onboard thermistor that measures the temperature of the electronics and will remove motor
current if the operating temperature exceeds this 203°F/95°C limit. This ovetemperature fault is also reported
in the Network Input Data.
1.4 Mounting
All AMCI motors have flanges on the front of the motor for mounting. This flange also acts as a heatsink, so
motors should be mounted on a large, unpainted metal surface. Mounting a motor in this fashion will allow a
significant amount of heat to be dissipated away from the motor, which will increase the unit’s life by reduc-
ing its operating temperature. This also allows higher current setting in environments with elevated ambient
temperatures. If you cannot mount the motor on a large metal surface, you may need to install a fan to force
cooling air over the unit.
Motors should be mounted using hardware with a minimum strength rating of 8.8 whenever possible. AMCI
motors can produce high torques and accelerations that may weaken and shear inadequate mounting hard-
ware.
1) The motor case must be grounded for proper operation. This is usually accomplished
through its mounting hardware. If you suspect a problem with your installation, such as
mounting the motor to a painted surface, then run a bonding wire from the motor to a solid
earth ground point near it. Use a minimum #14 gauge stranded wire or 1/4” wire braid as
the grounding wire
2) Do not disassemble
any
stepper motor. A significant reduction in motor performance will
result.
1.4.1 SMD17K-M12 Mounting
The SMD17K-M12 units are not water tight. Their IP50 rating makes them acceptable for use in dusty envi-
ronments with occasional condensation. These units should be mounted in such a way that condensation will
naturally drain off of the unit instead of pooling at the motor shaft, where the motor wires exit the motor, or
on the motor laminations.
Содержание SMD17K
Страница 1: ...MICRO CONTROLS INC ADVANCED U s e r M anual Manual 940 0S292...
Страница 6: ...TABLE OF CONTENTS SMD17K User Manual ADVANCED MICRO CONTROLS INC 6 Notes...
Страница 48: ...CALCULATING MOVE PROFILES SMD17K User Manual ADVANCED MICRO CONTROLS INC 48 Notes...
Страница 76: ...COMMAND DATA FORMAT SMD17K User Manual ADVANCED MICRO CONTROLS INC 76 Notes...
Страница 94: ...LEADERS IN ADVANCED CONTROL PRODUCTS ADVANCED MICRO CONTROLS INC...
Страница 96: ...DISTRIBUTED CLOCK SYNC0 SETUP SMD17K User Manual ADVANCED MICRO CONTROLS INC 96...
Страница 98: ...DISTRIBUTED CLOCK SYNC0 SETUP SMD17K User Manual ADVANCED MICRO CONTROLS INC 98...