![AMCI SMD17K Скачать руководство пользователя страница 56](http://html1.mh-extra.com/html/amci/smd17k/smd17k_user-manual_2921174056.webp)
C
ONFIGURATION
D
ATA
F
ORMAT
SMD17K User Manual
ADVANCED MICRO CONTROLS INC.
56
Data Format (continued)
CFG_Word_0 Format (continued)
Bit 12: Reserved –
Must equal zero.
Bit 11: Use_Backplane_Proximity –
“0” when the Backplane_Proximity_Bit is not used when homing the
SMD17K. “1” when the Backplane_Proximity_Bit is used when homing the unit. Note that this bit is
not the Backplane_Proximity_Bit, but enables or disables its operation. Do not use the
Backplane_Proximity_Bit if you only want to home to a Home Limit Switch. (Leave this bit equal to
“0”.) If you enable this bit and then never turn on the Backplane_Proximity_Bit, the SMD17K unit
will ignore all transitions of the home limit switch and you will not be able to home the device.
Bit 10: Use_Encoder –
Reset to “0” when the built-in encoder is not used or not available. Set to “1” to
enable the built-in absolute or quadrature encoder. When enabled, you must also program the
Encoder_Resolution parameter in CoE index 8010:05.
Bits 9-6: Reserved –
Must equal “0”.
Bits 5-3: Input 2 Function –
See the table below.
Bits 2-0: Input 1 Function –
See the table below.
Table R5.2 Configuration Data: Input Function Selections
Bits
5
4
3
2
1
0
Function
Available On
0
0
0
General Purpose Input
The input is not used in any of the functions of the
SMD17K, but it’s status is reported in the Network Data.
This allows the input to be used as a discrete DC input to
the host controller.
0
0
1
CW Limit
Input defines the mechanical end point for CW motion.
0
1
0
CCW Limit
Input defines the mechanical end point for CCW motion.
0
1
1
Start Indexed Move
Starts the move that is currently located in the output reg-
isters.
0
1
1
Start Indexed Move /
Capture Encoder Value
When the encoder is enabled on an SMD17K, the encoder
position value is captured whenever this input transitions.
An inactive-to-active state transition will also trigger an
Indexed Move if one is pending in the SMD17K.
1
0
0
Stop Jog or
Registration Move
Brings a Jog or Registration Move to a controlled stop.
1
0
0
Stop Jog or
Registration Move
&
Capture Encoder Value
When the encoder is enabled on an SMD17K, the encoder
position value is captured when the input triggers a con-
trolled stop to a Jog or Registration move.
1
0
1
Emergency Stop
All motion is immediately stopped when this input makes
an inactive-to-active transition.
1
1
0
Home
Used to define the home position of the machine.
1
1
1
Invalid Combination
This bit combination is reserved.
Содержание SMD17K
Страница 1: ...MICRO CONTROLS INC ADVANCED U s e r M anual Manual 940 0S292...
Страница 6: ...TABLE OF CONTENTS SMD17K User Manual ADVANCED MICRO CONTROLS INC 6 Notes...
Страница 48: ...CALCULATING MOVE PROFILES SMD17K User Manual ADVANCED MICRO CONTROLS INC 48 Notes...
Страница 76: ...COMMAND DATA FORMAT SMD17K User Manual ADVANCED MICRO CONTROLS INC 76 Notes...
Страница 94: ...LEADERS IN ADVANCED CONTROL PRODUCTS ADVANCED MICRO CONTROLS INC...
Страница 96: ...DISTRIBUTED CLOCK SYNC0 SETUP SMD17K User Manual ADVANCED MICRO CONTROLS INC 96...
Страница 98: ...DISTRIBUTED CLOCK SYNC0 SETUP SMD17K User Manual ADVANCED MICRO CONTROLS INC 98...