![AMCI SMD17K Скачать руководство пользователя страница 41](http://html1.mh-extra.com/html/amci/smd17k/smd17k_user-manual_2921174041.webp)
20 Gear Drive, Plymouth Ind. Park, Terryville, CT 06786
Tel: (860) 585-1254 Fax: (860) 584-1973 http://www.amci.com
SMD17K User Manual
C
ALCULATING
M
OVE
P
ROFILES
41
Constant Acceleration Equations (continued)
Continuing the example from table R3.2, assume a total travel distance of 300,000 steps.
Once you have calculated the maximum speed, you can substitute this value into the time and distance formu-
las in table R3.1 to calculate time spent and distance traveled while accelerating and decelerating.
Total Time Equations
For Trapezoidal Profiles you must first determine the number of counts that you are running at the Pro-
grammed Speed. This value, (D
P
below), is equal to your D
A
and D
D
values subtracted from your total travel.
You can then calculate your total profile time, (T
P
below), from the second equation.
D
P
= (Total Number of Steps) – (D
A
+ D
D
)
T
P
= T
A
+ T
D
+ D
P
/V
P
For Triangular Profiles, the total time of travel is simply:
T
P
= T
A
+ T
D
D
A
D
D
+
V
M
2
V
S
2
–
2
a
--------------------
V
M
2
V
S
2
–
2
d
--------------------
+
=
300,000 steps
V
M
2
141
2
–
2 20,000
-------------------------
V
M
2
141
2
–
2 25,000
-------------------------
+
=
300,000 steps
V
M
2
20,000
–
40,000
------------------------------
V
M
2
20,000
–
50,000
------------------------------
+
=
300,000 steps
5
5
---
V
M
2
20,000
–
40,000
------------------------------
4
4
---
V
M
2
20,000
–
50,000
------------------------------
+
=
300,000 steps
5
V
M
2
100,000
–
200,000
------------------------------------
4
V
M
2
80,000
–
200,000
---------------------------------
+
=
300,000 (200,000)
9
V
M
2
180,000
–
=
60,000.18
10
6
9
--------------------------------------
V
M
2
=
V
M
81,650 steps/sec
=
Содержание SMD17K
Страница 1: ...MICRO CONTROLS INC ADVANCED U s e r M anual Manual 940 0S292...
Страница 6: ...TABLE OF CONTENTS SMD17K User Manual ADVANCED MICRO CONTROLS INC 6 Notes...
Страница 48: ...CALCULATING MOVE PROFILES SMD17K User Manual ADVANCED MICRO CONTROLS INC 48 Notes...
Страница 76: ...COMMAND DATA FORMAT SMD17K User Manual ADVANCED MICRO CONTROLS INC 76 Notes...
Страница 94: ...LEADERS IN ADVANCED CONTROL PRODUCTS ADVANCED MICRO CONTROLS INC...
Страница 96: ...DISTRIBUTED CLOCK SYNC0 SETUP SMD17K User Manual ADVANCED MICRO CONTROLS INC 96...
Страница 98: ...DISTRIBUTED CLOCK SYNC0 SETUP SMD17K User Manual ADVANCED MICRO CONTROLS INC 98...