![AMCI SMD17K Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/amci/smd17k/smd17k_user-manual_2921174011.webp)
20 Gear Drive, Plymouth Ind. Park, Terryville, CT 06786
Tel: (860) 585-1254 Fax: (860) 584-1973 http://www.amci.com
SMD17K User Manual
SMD17K S
PECIFICATIONS
11
The SMD17K Family (continued)
General Functionality (continued)
The SMD17K units have two DC inputs that are used by the indexer. Configuration data from the host sets the
function of these inputs. Each input can be individually configured as a:
CW or CCW Limit Switch
Home Limit Switch
Capture Position Input (Will capture encoder position on units with the internal encoder.)
Stop Jog or Registration Move Input
Start Indexer Move
Emergency Stop Input
General Purpose Input
Encoder Functionality
All SMD17K units can be ordered with an internal incremental or absolute multi-turn encoder. Incremental
encoders can be programmed to 1,024, 2,048, or 4,069 counts per turn. Absolute encoders have a fixed reso-
lution of 2,048 counts per turn and encode a total of 2
21
turns. (32 bits total.) Using an encoder gives you the
ability to:
Verify position during or after a move
Detect motor stall conditions
Maintain machine position when power is removed if using an absolute encoder.
The motor position can be preset to the encoder position with a single command. SMD17K units with abso-
lute encoders allow you to preset the encoder position and save the resulting offset in Flash memory.
Conformance Markings
The SMD17K family meets the requirements for the following conformance markings when installed and
operated in accordance with the instructions contained in the product documentation.
UL
Recognized component in the USA and Canada.
US: UL 61800-5-1 Standard For Safety For Adjustable Speed Electrical Power Drive Systems - Part
5-1: Safety Requirements - Electrical, Thermal and Energy
Canada: CSA C22.2 No. 274 - Adjustable Speed Drives
CE
Directive 2014/30/EU of the European Parliament and of the Council (EMC), of 26 February 2014 on
the harmonisation of the laws of the Member States relating to electromagnetic compatibility; per EN
61800-3:2004/A1:2012.
Directive 2014/35/EU of the European Parliament and of the Council (Low Voltage), of 26 February
2014 on the harmonisation of the laws of the Member States relating to the making available on the
market of electrical equipment designed for use within certain voltage limits; per EN 61010-1:2010.
RoHS
Directive (EU) 2015/863 (RoHS 3) and Directive 2011/65/EU (RoHS 2)
Содержание SMD17K
Страница 1: ...MICRO CONTROLS INC ADVANCED U s e r M anual Manual 940 0S292...
Страница 6: ...TABLE OF CONTENTS SMD17K User Manual ADVANCED MICRO CONTROLS INC 6 Notes...
Страница 48: ...CALCULATING MOVE PROFILES SMD17K User Manual ADVANCED MICRO CONTROLS INC 48 Notes...
Страница 76: ...COMMAND DATA FORMAT SMD17K User Manual ADVANCED MICRO CONTROLS INC 76 Notes...
Страница 94: ...LEADERS IN ADVANCED CONTROL PRODUCTS ADVANCED MICRO CONTROLS INC...
Страница 96: ...DISTRIBUTED CLOCK SYNC0 SETUP SMD17K User Manual ADVANCED MICRO CONTROLS INC 96...