Controlling Find Home Commands In Progress
Controlled Stop Conditions
The move completes without error.
You issue a Hold Move command through the Network Output Data. This will abort the command and
the axis will decelerate at the programmed rate until it reaches the Starting Speed. At this point, the
motor will stop. Note that Find Home commands cannot be restarted once held.
Immediate Stop Conditions
You issue an Immediate Stop command through the Network Output Data.
An inactive-to-active transition on an input configured as an E-Stop Input.
The overtravel limit associated with travel in the opposite direction is activated. i.e. Activating the
CCW limit during a CW Find Home command. This can occur if the overtravel limits are not wired to
the SMD17K correctly, or not configured correctly when the unit was configured.
Содержание SMD17K
Страница 1: ...MICRO CONTROLS INC ADVANCED U s e r M anual Manual 940 0S292...
Страница 6: ...TABLE OF CONTENTS SMD17K User Manual ADVANCED MICRO CONTROLS INC 6 Notes...
Страница 48: ...CALCULATING MOVE PROFILES SMD17K User Manual ADVANCED MICRO CONTROLS INC 48 Notes...
Страница 76: ...COMMAND DATA FORMAT SMD17K User Manual ADVANCED MICRO CONTROLS INC 76 Notes...
Страница 94: ...LEADERS IN ADVANCED CONTROL PRODUCTS ADVANCED MICRO CONTROLS INC...
Страница 96: ...DISTRIBUTED CLOCK SYNC0 SETUP SMD17K User Manual ADVANCED MICRO CONTROLS INC 96...
Страница 98: ...DISTRIBUTED CLOCK SYNC0 SETUP SMD17K User Manual ADVANCED MICRO CONTROLS INC 98...