Homing Profiles (continued)
Profile with Backplane_Proximity_Bit
Figure R4.2 below shows the move profile generated by a CW Find Home command when you use the Home
Input with Backplane_Proximity_Bit.
Figure R4.2 Homing with Proximity
1)Acceleration from the configured Starting Speed to the Programmed Speed
2)Run at the Programmed Speed
3)Ignores the Home Input because Backplane_Proximity_Bit has not made a 0
1 transition.
4)Deceleration towards the Starting Speed when the Backplane_Proximity_Bit transitions from 0 to 1.
The axis will stop as soon as the Home Input becomes active.
5)The Starting Speed is the minimum speed the profile will run at. If the axis decelerates to the Starting
Speed before reaching the Home Input, it will continue at this speed.
Figure R4.2 shows the Backplane_Proximity_Bit staying active until the SMD17K reaches its
home position. This is valid, but does not have to occur. As stated in step 4, the unit starts to
hunt for the home position as soon as the Backplane_Proximity_Bit makes a 0
1 transition.
(CW)
(CCW)
S
P
E
E
D
POSITION
Home
Proximity Bit
Active
Home
Input
Home Input
Содержание SMD17K
Страница 1: ...MICRO CONTROLS INC ADVANCED U s e r M anual Manual 940 0S292...
Страница 6: ...TABLE OF CONTENTS SMD17K User Manual ADVANCED MICRO CONTROLS INC 6 Notes...
Страница 48: ...CALCULATING MOVE PROFILES SMD17K User Manual ADVANCED MICRO CONTROLS INC 48 Notes...
Страница 76: ...COMMAND DATA FORMAT SMD17K User Manual ADVANCED MICRO CONTROLS INC 76 Notes...
Страница 94: ...LEADERS IN ADVANCED CONTROL PRODUCTS ADVANCED MICRO CONTROLS INC...
Страница 96: ...DISTRIBUTED CLOCK SYNC0 SETUP SMD17K User Manual ADVANCED MICRO CONTROLS INC 96...
Страница 98: ...DISTRIBUTED CLOCK SYNC0 SETUP SMD17K User Manual ADVANCED MICRO CONTROLS INC 98...