Available Discrete Inputs (continued)
CW Limit Switch or CCW Limit Switch
Each input can be defined as a CW or CCW Limit Switch. When used this way, the inputs are used to define
the limits of mechanical travel. For example, if you are moving in a clockwise direction and the CW Limit
Switch activates, all motion will immediately stop. At this point, you will only be able to jog in the counter-
clockwise direction.
Start Indexer Move Input
Indexer Moves are programmed through the Network Data like every other move. The only difference is that
Indexer Moves are not run until a Start Indexer Move Input makes a inactive-to-active state transition. This
allows an SMD17K to run critically timed moves that cannot be reliably started from the network due to data
transfer lags.
If the unit was ordered with the encoder option, and one of the discrete DC inputs is programmed as a Start
Indexer Move Input, then the encoder position data will be captured whenever the DC input makes a transi-
tion. An inactive-to-active state transition on the DC input will also trigger an Indexer Move if one is pend-
ing.
Emergency Stop Input
When an input is defined as an Emergency Stop, or E-Stop Input, motion will immediately stop when this
input becomes active. The driver remains enabled and power is supplied to the motor. Any type of move,
including a Jog or Registration Move, cannot begin while this input is active.
Stop Jog or Registration Move Input
When an input is configured as a Stop Jog or Registration Move Input, triggering this input during a Jog
Move or Registration Move will bring the move to a controlled stop. The controlled stop is triggered on an
inactive-to-active state change on the input. Only Jog Moves and Registration Moves can be stopped this
way, all other moves ignore this input.
If the unit was order with an integral encoder, the encoder position data will be captured when the DC input
makes an inactive-to-active transition if it is configured as a Stop Jog or Registration Move Input. The
encoder position data is not captured if a Jog or Registration Move is not in progress. If you want to capture
encoder position data on every transition of a DC input, configure it as a Start Indexer Move Input.
Capture Encoder Position Input
As described in the
and
Stop Jog or Registration Move Input
sections above, an
SMD17K can be configured to capture the encoder position value on a transition of a discrete DC input.
General Purpose Input
If your application does not require one or both of the inputs, you can configure the unused inputs as General
Purpose Inputs. The inputs are not used by the SMD17K, but their on/off state is reported in the network data
and is available to your host controller.
Содержание SMD17K
Страница 1: ...MICRO CONTROLS INC ADVANCED U s e r M anual Manual 940 0S292...
Страница 6: ...TABLE OF CONTENTS SMD17K User Manual ADVANCED MICRO CONTROLS INC 6 Notes...
Страница 48: ...CALCULATING MOVE PROFILES SMD17K User Manual ADVANCED MICRO CONTROLS INC 48 Notes...
Страница 76: ...COMMAND DATA FORMAT SMD17K User Manual ADVANCED MICRO CONTROLS INC 76 Notes...
Страница 94: ...LEADERS IN ADVANCED CONTROL PRODUCTS ADVANCED MICRO CONTROLS INC...
Страница 96: ...DISTRIBUTED CLOCK SYNC0 SETUP SMD17K User Manual ADVANCED MICRO CONTROLS INC 96...
Страница 98: ...DISTRIBUTED CLOCK SYNC0 SETUP SMD17K User Manual ADVANCED MICRO CONTROLS INC 98...