20 Gear Drive, Plymouth Ind. Park, Terryville, CT 06786
Tel: (860) 585-1254 Fax: (860) 584-1973 http://www.amci.com
SD4840EK User Manual
M
OVE
P
ROFILES
31
Assembled Moves (continued)
Blend Moves (continued)
Controlled Stops
The move completes without error.
You toggle the Hold Move control bit in the Network Output Data. When this occurs, the SD4840EK
decelerates the move at the deceleration rate of the present segment to the Starting Speed and ends the
move. Note that your final position will most likely not be the one you commanded. The use of the Hold
Move bit is explained in the
Immediate Stops
The Immediate Stop bit makes a 0
1 transition in the Network Output Data.
A positive transition on an input configured as an E-Stop Input.
A CW/CWW Limit Switch is reached. If the limit that is reached is the same as the direction of travel,
for example, hitting the CW limit while running a CW move, a
Reset Errors
command must be issued
before moves are allowed in that direction again. If the limit that is reached is opposite the direction of
travel, a
Reset Errors
command does not have to be issued.
Dwell Move
A Dwell Move gives you the ability to string multiple relative moves together and run all of them sequentially
with a single start condition. Like a Blend Move, a Dwell Move is programmed into the SD4840EK as a series
of relative moves before the move is started.
Unlike a Blend Move, the motor is stopped between each segment of the Dwell Move for a programed
Dwell
Time
. The Dwell Time is programmed with the command that starts the Dwell Time. The same Dwell Time is
used between segments. Because the motor is stopped between segments, the motor direction can be reversed
during the move. The sign of the target position for the segment determines the direction of motion for that
segment. Positive segments will result in clockwise moves while a negative segment will result in a counter-
clockwise move. The following figure shows a drilling profile that enters the part in stages and reverses direc-
tion during the drilling operation so chips can be relieved from the bit.
You can accomplish this Dwell Move with a series of six relative moves that are sent down to the SD4840EK
sequentially. The two advantages of a Dwell Move in this case is that the SD4840EK will be more accurate
with the Dwell Time then you could accomplish in the PLC, and Dwell Moves simplifies your program’s
logic.
Figure R2.13 Dwell Move
SP
E
ED
POSITION
CW
CCW
Segment 1
Segment 2
Segment 4
Segment 6
Segment 3
Segment 5
Содержание SD4840EK
Страница 1: ...MICRO CONTROLS INC ADVANCED U s e r M anual Manual 940 0S310...
Страница 6: ...TABLE OF CONTENTS SD4840EK User Manual ADVANCED MICRO CONTROLS INC 6 Notes...
Страница 38: ...MOVE PROFILES SD4840EK User Manual ADVANCED MICRO CONTROLS INC 38 Notes...
Страница 48: ...CALCULATING MOVE PROFILES SD4840EK User Manual ADVANCED MICRO CONTROLS INC 48 Notes...
Страница 78: ...COMMAND DATA FORMAT SD4840EK User Manual ADVANCED MICRO CONTROLS INC 78 Notes...
Страница 94: ...INSTALLING THE SD4840EK SD4840EK User Manual ADVANCED MICRO CONTROLS INC 94 Notes...
Страница 104: ...LEADERS IN ADVANCED CONTROL PRODUCTS ADVANCED MICRO CONTROLS INC...