Controlled and Immediate Stops
Once a move is started, there are several ways to stop the move before it comes to an end. These stops are
broken down into two types:
Controlled Stop:
The axis immediately begins decelerating at the move’s programmed deceleration
value until it reaches the configured Starting Speed. The axis stops at this point. The motor position
value is still considered valid after a Controlled Stop and the machine does not need to be homed again
before Absolute Moves can be run.
Immediate Stop:
The axis immediately stops outputting pulses regardless of the speed the motor is run-
ning at. Because it is possible for the inertia of the load attached to the motor to pull the motor beyond
the stopping point, the motor position value is considered invalid after an Immediate Stop and the
machine must be homed again before Absolute Moves can be run.
Host Control
Hold Move Command:
This command can be used with some moves to bring the axis to a Controlled Stop.
The move can be resumed and finished, or it can be aborted. Not all moves are affected by this command. The
section
, starting on page 24, describes each move type in detail, including if the move is
affected by this command.
Immediate Stop Command:
When this command is issued from the host, the axis will come to an Immediate
Stop. The move cannot be restarted and the machine must be homed again before Absolute Moves can be run.
Hardware Control
Stop Jog or Registration Move Input:
Triggering this input type during a Jog Move or Registration Move will
bring the move to a controlled stop. The controlled stop is triggered on an inactive-to-active state change on the
input. Only Jog Moves and Registration Moves can be stopped this way, all other moves ignore this input.
CW Limit and CCW Limit Inputs:
In most cases, activating these inputs during a move will bring the axis to
an Immediate Stop. The exceptions are the
CW/CCW Find Home
commands, the
CW/CCW Jog Move
com-
mands, and the
CW/CCW Registration Move
commands. The
CW/CCW Find Home
commands are explained
in chapter 3,
, which starts on page 49. The
commands are fully
commands are fully explained on page 27.
Emergency Stop Input:
It is possible to configure an input as an Emergency Stop Input. When an Emergency
Stop Input is activated, the axis will come to an Immediate Stop, regardless of the direction of travel.
Содержание SD4840EK
Страница 1: ...MICRO CONTROLS INC ADVANCED U s e r M anual Manual 940 0S310...
Страница 6: ...TABLE OF CONTENTS SD4840EK User Manual ADVANCED MICRO CONTROLS INC 6 Notes...
Страница 38: ...MOVE PROFILES SD4840EK User Manual ADVANCED MICRO CONTROLS INC 38 Notes...
Страница 48: ...CALCULATING MOVE PROFILES SD4840EK User Manual ADVANCED MICRO CONTROLS INC 48 Notes...
Страница 78: ...COMMAND DATA FORMAT SD4840EK User Manual ADVANCED MICRO CONTROLS INC 78 Notes...
Страница 94: ...INSTALLING THE SD4840EK SD4840EK User Manual ADVANCED MICRO CONTROLS INC 94 Notes...
Страница 104: ...LEADERS IN ADVANCED CONTROL PRODUCTS ADVANCED MICRO CONTROLS INC...