Basic Move Types (continued)
CW/CCW Jog Move (continued)
Immediate Stops
The Immediate Stop bit makes a 0
1 transition in the Network Output Data.
A inactive-to-active transition on an input configured as an E-Stop Input.
A CW/CWW Limit Switch is reached. If the limit that is reached is the same as the direction of travel,
for example, hitting the CW limit while running a CW move, a
Reset Errors
command must be issued
before moves are allowed in that direction again. If the limit that is reached is opposite the direction of
travel, a
Reset Errors
command does not have to be issued.
Note that it is possible to
start
a move while a CW or CCW Limit Switch is active as long as
the direction of travel is
opposite
that of the activated Limit Switch. For example, it is possible
to start a clockwise Jog Move while the CCW Limit Switch is active.
CW/CCW Registration Move
Similar to a Jog Move, a Registration Move will travel in the programmed direction as long as the command
is active. CW Registration Moves will cause clockwise motion when the motor is wired as shown in this man-
ual, while CCW Registration Moves will cause counter-clockwise motion. When the command terminates
under Controlled Stop conditions, the SD4840EK will output a programmed number of steps as part of bring-
ing the move to a stop. Note that all position values programmed with a Registration Move are relative val-
ues, not absolute machine positions.
Figure R2.9 Registration Move
If the Programmed Number of Steps are less than the number of steps needed to bring the axis to a stop based
on the Programmed Speed and Deceleration values set with the command, the SD4840EK will decelerate at
the programmed Deceleration value until it has output the Programmed Number of Steps and then stop the
move without further deceleration.
S
PEE
D
POSITION
Controlled
Stop Condition
Содержание SD4840EK
Страница 1: ...MICRO CONTROLS INC ADVANCED U s e r M anual Manual 940 0S310...
Страница 6: ...TABLE OF CONTENTS SD4840EK User Manual ADVANCED MICRO CONTROLS INC 6 Notes...
Страница 38: ...MOVE PROFILES SD4840EK User Manual ADVANCED MICRO CONTROLS INC 38 Notes...
Страница 48: ...CALCULATING MOVE PROFILES SD4840EK User Manual ADVANCED MICRO CONTROLS INC 48 Notes...
Страница 78: ...COMMAND DATA FORMAT SD4840EK User Manual ADVANCED MICRO CONTROLS INC 78 Notes...
Страница 94: ...INSTALLING THE SD4840EK SD4840EK User Manual ADVANCED MICRO CONTROLS INC 94 Notes...
Страница 104: ...LEADERS IN ADVANCED CONTROL PRODUCTS ADVANCED MICRO CONTROLS INC...