6.3.9 Adjusting the fan speed
REQUIREMENTS
The hopper is full
The hopper is closed
DANGER
Risk of injury due to parts of the fan being
flung out
If the fan is operated at excessive speeds,
fan parts can break and be flung out.
Make sure that the fan speed does not
exceed 5000 rpm.
NOTE
The specifications for the fan speed are
recommendations. If seed remains in the hose
package or is blown out of the seedbed, the
setting must be adjusted.
CMS-I-00004431
1.
Read the fan speed for fertiliser
1
, seed
2
or
fine seeds
3
from the table.
2.
To correct the fan speed,
adjust the oil quantity on the tractor control unit.
3.
Check the fan pressure on the pressure gauge
1
.
If the pressure gauges do not display appreciable
pressure when the fan is running, check if the
hopper cover and the calibration flaps are closed.
CMS-I-00002487
CMS-T-00003208-D.1
6 | Preparing the machine
Preparing the implement for operation
MG6492-EN-II | G.1 | 26.04.2021
71