9.3 Eliminating faults
Errors
Cause
Solution
The control terminal displays a fan
speed that is too high.
The hydraulic control unit is
incorrectly adjusted.
To adjust the fan speed,
see "Setting the fan speed".
The control terminal displays a
metering shaft speed that is too
low.
The metering roller is rotating stiffly.
To check the metering unit,
see "Calibrating the spread
rate".
The metering roller is blocked by
foreign objects in the metering
housing.
To clean the metering unit,
see "Cleaning the metering
unit".
The electric drives do not run or
start running at the wrong time.
The switch points of the working
position sensor are wrong.
To configure the working
position sensor,
see "Configuring the working
position sensor".
9.4 Cleaning the machine
IMPORTANT
Risk of machine damage due to cleaning
jet of the high-pressure nozzle
Never direct the cleaning jet of the
high-pressure cleaner or hot water
high-pressure cleaner onto the marked
components.
Never aim the cleaning jet of high-
pressure cleaners or hot water high-
pressure cleaners on electrical or
electronic components.
Never aim the cleaning jet of the high
pressure cleaner directly on lubrication
points, bearings, rating plates, warning
signs, and stickers.
Always maintain a minimum distance
of 300 mm between the high-pressure
nozzle and the machine.
Do not exceed a water pressure of 120
bar.
Clean the machine with a high-pressure cleaner
or a hot water high-pressure cleaner.
CMS-T-00003128-A.1
CMS-T-00000593-C.1
9 | Repairing the machine
Eliminating faults
MG6492-EN-II | G.1 | 26.04.2021
122