5.
To wash the deposits out of the conveyor hoses
3
,
direct a jet of water through the calibration
openings
2
into the conveyor hoses.
6.
When most of the water has escaped through
the calibration opening,
close the calibration flaps
2
with the locks
1
.
7.
Run the fan for about 5 minutes.
The air supply is blown dry.
8.
Switch off the fan.
1
2
3
CMS-I-00002508
9.1.5 Cleaning the cyclone separator
INTERVAL
Every 10 operating hours
or
daily
For the cyclone separator to work, the separator
opening
3
must be free of impurities.
1.
Check the separator opening
3
.
2.
If the separator opening in clogged,
open the clips
2
.
3.
Loosen the wing nut
1
.
4.
Remove the cover and clean it.
5.
Install the cover with the wing nut.
6.
Fasten the suction cage with the clips.
1
2
3
CMS-I-00002765
CMS-T-00003779-B.1
9 | Repairing the machine
Maintaining the machine
MG6492-EN-II | G.1 | 26.04.2021
106