![Amazone FTender 1600 Скачать руководство пользователя страница 116](http://html1.mh-extra.com/html/amazone/ftender-1600/ftender-1600_original-operating-manual_2919754116.webp)
12. Loosen the bolts with the wrench
1
.
13. Park the wrench in the holder
3
.
14.
To align the notches in the bearing cover flush
with the bolts,
Turn the bearing cover
2
.
1
3
2
CMS-I-00002501
15. Pull off the bearing cover
2
.
16.
When the hopper is closed off with the sliding
shutter
1
,
pull the metering roller
3
out of the metering
unit.
17. Clean the metering housing and the metering
roller.
18.
When the metering housing and the metering
roller have been cleaned,
reinstall the metering roller.
ME1405
1
2
CMS-I-00002512
19. Align the catch
3
on the bearing cover
2
with
the drive shaft.
20. Install the bearing cover.
21. Tighten the bolts with the wrench
1
.
22. Park the wrench in the holder
4
.
1
4
2
3
CMS-I-00002504
9 | Repairing the machine
Maintaining the machine
MG6492-EN-II | G.1 | 26.04.2021
110