12
SPECIFICATIONS
HEAT PUMP - PTH
PTH G SERIES
* Actual vent CFM performance will vary due to application and installation conditions.
Notes:
¹ All 265-volt models must use an Amana® brand sub-base (PTSB4**E) or an Amana® brand hard-wire kit (PTPWHWK4).
² Minimum Circuit Ampacity (MCA) ratings conform to the National Electric Code; however, local codes should apply.
Minimum voltage on 230/208-volt models is 197 volts; maximum is 253 volts.
³ Minimum voltage on 265-volt models is 239 volts; maximum is 292 volts.
5
Heating capacity and efficiency based on unit operation without condensate pump; unit automatically switches to electric heat at approximately 24°F outdoor ambient.
6
Specify two-digit heater kW size to complete model number.
7
R-410A refrigerant used in all systems.
8
All units meet or exceed ASHRAE 90.1 standards.
9
All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards.
10
Refer to electric heat performance data for total MCA and recommended overcurrent protection. Amps and Watts notation refers to com pressor only.
4
Overcurrent protection for all units without electric heaters is 15 amps. Overcurrent protection on 265-volt models must be cartridge-style time-delay fuses
(included and factory-installed on all Amana® brand 265-volt chassis). See heater performance for total MCA.
EER -
Energy Efficiency Ratio per The Air-Conditioning,
Heating, and Refrigeration Institute (AHRI) Test
Procedures and Canadian Standards Association
(CSA) Test Procedures.
COP -
Coefficient of Performance per AHRI Test
Procedures
Model ¹,
6
,
8
,
9
PTH
073G**AXXX
PTH
093G**AXXX
PTH
123G**AXXX
PTH
153G**AXXX
PTH
074G**AXXX
PTH
094G**AXXX
PTH
124G**AXXX
PTH
154G**AXXX
230 / 208
230 / 208
230 / 208
230 / 208
265
265
265
265
7,700 / 7,700 9,000 / 9,000 12,000 / 12,000 14,400 / 14,400
7,700
9,100
12,000
14,400
3.9 / 3.9
4.2 / 4.2
5.8 / 5.8
7.0 / 7.0
3.1
3.7
5.0
6.1
655 / 655
785 / 785
1,125 / 1,100
1,480 / 1,480
655
790
1,120
1,480
EER
11.7 / 11.7
11.5 / 11.5
10.7 / 10.7
9.7 / 9.7
11.7
11.5
10.7
9.7
Unit without Electric Heater
4.7
5.1
7.1
8.5
3.8
4.5
6.1
7.4
High
340
330
340
390
340
330
340
390
Low
245
245
245
340
245
245
245
340
High
370
360
370
410
370
360
370
410
Low
270
270
270
370
270
270
270
370
65*
65*
65*
65*
65*
65*
65*
65*
(Compressor & Fan)*
40*
40*
40*
40*
40*
40*
40*
40*
1.7
2.2
3.6
4.4
1.7
2.2
3.6
4.4
108
112
115
126
108
112
115
125
123
127
132
143
123
127
132
142
Voltage ¹, ³
Capacity (BTU/h)
Amps
10
Watts
10
CFM (Dry Coil)
Ventilated Air, CFM (Fan Only)*
Ventilated Air, CFM
Ship Weight (lbs.)
Min. Circuit Amps ²,
4
,
10
CFM (Cool/Wet Coil)
Dehumidification (Pints/Hr.)
Net Weight (lbs.)