SCHEMATICS
WARNING
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
RD
RD
BL
HEATER 2
HEATER 1
COMPRES SOR
BK
FAN
HIGH
FAN
LOW
REV
VALV E
RD
R
BK
BK
BK
COM
GND
230/265
TO MOTOR
VSTM OD
R 485
S
RD
GN
EM
FAN
MOTOR
BK
BR
BR
RD
BK
FOR A HEAT PUMP
THERMOSTAT USED
ON A STRAIGHT
COOL UNIT
GL - LOW SPEED
GH - HIGH SPEED
7
STANDARD
PTH**G*****A* (ID MOTOR 2 SPEED PSC; OD MOTOR DC)
DRY***G**AXXX**
Model
Starts With
PTH073G
(00 to 35)
1350
M3
1170
M4
DRY093G
(00 to 35)
1350
M3
1170
M4
DRY094G
(00 to 35)
1350
M3
1170
M4
High Speed
VSTM Black
Low Speed
VSTM Red
Outdoor Motor Speed Selection
CM
COMP
EM
FC
F
HPS
HTR
RCCF
RVC
TR
VSM
VSTM
R
OUTDOOR FAN MOTOR
COMPRESSOR
EVAPORATOR MOTOR
FAN CAPACITOR
FUSE
HIGH PRESSURE SWITCH
HEATER ELEMENT
RELAY
RUN CAPACITOR
FOR COMPRESSOR, AND FAN
REVERSING VALVE
TRANSFORMER
VARIABLE SPEED MOTOR