SERVICING
POWER CORD
1. Remove the unit front by tilting the bottom of the front
outward and then lift the front straight up.
2. Remove the control knobs on the control panel cover by
pulling upward on the knobs. Remove the escutcheon.
3. Remove the control panel cover by removing the two
screws holding the control panel cover. Tilt the control
panel forward to gain access to the wires.
4. Remove the power cord clamp located near the bottom
right of the chassis.
Control
Panel
Power
Incoming
Power
Opening
Right Side
Of Unit
Power Cord Clamp
5. On
230/208 volt
units disconnect the ribbed lead from
the C terminal on the capacitor and the smooth lead
from LINE 2 terminal on the control board and the green
ground wire from the partition panel.
On
265 volt
units disconnect the ribbed lead from the C
terminal on the capacitor and the smooth lead from the
fuse holder and the green ground wire from the parti-
tion panel.
LINE1 HEATER HEATER LINE 2
COMP
FAN
HIGH
FAN
LOW
R-VALVE
X
X
H
C
F
Ribbed Wire
BK18
BK18 on LINE 2 with fuse shown
connected is for 265 volt units. For
230/208 volt units, connect power
cord to LINE 2.
Control Panel
Capacitor
EVAPORATOR
1. Remove front cover.
2. Remove the two mounting screws, one on each side of
the control board cover. Tilting the control panel out,
disconnect ribbon connector from control board.
DO
NOT PULL ON RIBBON. GRASP THE BLACK RIBBON CON-
NECTOR AND PULL GENTLY.
3. Remove the two screws securing the top screen to the
evaporator assembly. (Be sure to slide the top of the
screen between the top flange and chassis when reas-
sembling.)
7. Remove screws on mid partition panel and shift out of
the way.
8. Remove the two screws securing the heater assembly
to the evaporator.
9. Pull heater assembly up and out of the chassis.
10. Disconnect all wiring to the heater assembly and re-
move the assembly.
11. Remove the floodback protector or thermistor from the
evaporator discharge tube.
12. Remove screws holding evaporator to basepan and par-
tition panel.
13. After recapturing the refrigerant charge (see Refrig-
eration Service section), debraze the tubes into the
evaporator. Be sure to protect all chassis components,
especially foam parts, from excessive heat.
14. Lift the evaporator up over the basepan edge and re-
move.
OUTDOOR COIL
1. Remove the chassis from the wall sleeve.
2. After capturing the refrigerant from the system, debraze
the inlet and discharge tubing from the outdoor coil.
3. Remove all screws from the sides of the outdoor coil
securing the shroud to the coil.
4. Pressing the tabs on the right side of the shroud sepa-
rate the shroud from the outdoor coil.
5. The "E-K" models have a four piece condenser shroud
where the top, sides and shroud will come apart sepa-
rately.
5. Remove the two screw securing the outdoor coil to the
base pan.
6. Carefully lift the outdoor coil over the basepan lip.
VENT DOOR
1. Remove Chassis from wall sleeve.
2. Remove P clamp securing vent door control cable to
center partition and disconnect cable from vent door.
3. Remove vent door by opening door and pulling hinge
tabs out of slots in center partition.
4. Remove the door by pulling hinge tabs out away from
the center partition.