64
MF-C2000A Series
8 . Connecting the Cable for the Heat Detector (Option)
8 . Connecting the Cable for the Heat Detector (Option)
To use the output unit corresponding to the active heat control, connect the cable for
the heat detector attached to the output unit.
Item required
Cable for the heat detector
Operating Procedure
(1) Confirm that the MAIN POWER switch is turned OFF.
(2) Open the connector cover on the rear to connect the cable for the heat detector
to the TH connector.
(3) Turn OFF the CONTROL keyswitch and turn ON the MAIN POWER switch.
Power is supplied and the POWER lamp comes on.
(4) While the KEY SWITCH CHECK screen is displayed, press the “INITIALIZE” but-
ton, pressing the right
button (red portion in the figure below) of the laser control
-
ler.
⇒
Unless the CONTROL keyswitch is OFF, the KEY SWITCH CHECK screen does
not appear.