1 . Maintenance Parts and Standard Intervals of Inspection/Replacement
217
MF-C2000A Series
Chapter 1 How to Perform Maintenance
Introduction Part
Operating Part
Maintenance Part
Appendixes
Installation
and
Preparation
Part
Part name
Model No .
or specification
Operation
interval
(standard) (*1)
Contents of
operation
(*2)
Protective glass
Specified glass for output unit
Every day
Clean
Every month
Replace
(*8)
Lithium battery (*9)
CR2032 3V
3 years
Replace
Memory card (*9)
Compliant with SD Specification
Ver3.01
3 years
Replace
Element assembly for AMH150
(*10)
AMH-EL150
2 years after
use
Replace
Membrane module for IDG3 (*10) IDG-EL3
10 years after
use
Replace
Dewpoint checker set for IDG3
(*10)
IDG-DP01
2 years after
use
Replace
Solenoid valve (*10)
VX210EGXCC
5 years
Replace
■
For the hatched portion, our engineer takes charge of maintenance work.
*1: The operation interval means the maintenance time or expected life of the
part, and is different from the warranty period.
*2: Part replacement is performed when any damage or defect is found or the
usable period ends.
*3: When the laser is stopped for a long time (for about one month), the usable
period of the lithium battery is shortened.
*4: The optical unit is the laser oscillator including the excitation LD. If the la-
ser output drops down and the processing conditions cannot be restored
despite setting the maximum output, it is determined as the end of its use-
ful life. The warranty is valid for a period of two years. However, usage out
of specifications, for example, failing to perform cleaning when connecting
the optical fiber described in the Installation and Preparation Part, Chapter
2 “5. Connecting the Optical Fiber” on page 58 or keep the bending radius
of the optical fiber, is not covered by the warranty.
*5: For option.
*6: The filter cartridge is the water filter used in the chiller.
*7: Use cooling water meeting water quality standard established by Japan
Refrigeration and Air Conditioning Industry Association (JRA GL-02-1994 /
cooling water system - cyclic water - makeup water).
*8: We do not specify a degree of parallelism of our standard protective glass.
Therefore, the condensing position may be shifted before and after replac-
ing the protective glass due to individual differences. The protective glass
having a very small positional deviation is also available. Contact us as
needed.
*9: Only for MF-C2000A-MC/SC
*10: Only when the dry air unit (option) is equipped
Содержание MF-C2000A Series
Страница 1: ...AA04OM1209213 07 FIBER LASER WELDER MF C2000A Series OPERATION MANUAL ...
Страница 21: ...Introduction Part ...
Страница 22: ......
Страница 34: ......
Страница 42: ......
Страница 43: ...Installation and Preparation Part ...
Страница 44: ......
Страница 73: ...Operating Part ...
Страница 74: ......
Страница 78: ......
Страница 142: ......
Страница 208: ...208 MF C2000A Series 4 Connector Functions REM I L Connector E STOP Connector Refer to the Operating Part Chapter 4 ...
Страница 212: ......
Страница 213: ...Maintenance Part ...
Страница 214: ......
Страница 232: ......
Страница 244: ......
Страница 245: ...Appendixes ...
Страница 246: ......