2 . Maintenance of the Laser Oscillator
221
MF-C2000A Series
Chapter 1 How to Perform Maintenance
Introduction Part
Operating Part
Maintenance Part
Appendixes
Installation
and
Preparation
Part
3
Correcting the Laser Output
(1) Display the MONITOR screen and depress the “POWER ADJ.” button for about 1
second.
(2) Set up the power meter. (Operate according to the display of the yellow line.)
Confirm that the power meter is placed at the proper position. After wearing
protective glasses and confirming that the safety against the scattered light is
ensured, press the
button.
(3) Press the "UP" button to increase the output and the "DOWN" button to decrease
it.
Adjust it within the range of gauge. One-clicking button with a value around the
rated output (2000 W) adjusts the output approx. 0.5% to 2%.